Page 10
HW-Series Gas Fireplace
Part No. XG0190 - 071409
Installation
Figure 12.
Extended Installation using a combination of solid and flex
venting. Use the vent graph to determine your allowable
run, then select appropriate components.
Figure 13.
Retracted Installation using a combination of solid and flex
venting. Use the vent graph to determine your allowable
run, then select appropriate components.
Figure 14.
Horizontal flex installation with no vertical rise.
B. Vertical (Through-The-Roof) Installations
Minimum clearances 2" from vent to all combustible materials must
be maintained.
A maximum of two offsets
(each offset has two 90° bends)
may be
made and shall not exceed total length of 25% of the vertical vent
height, when measured center to center of piping.
Example:
Typical vent installation.
20' vertical vent
2 - 2' offsets required
25% of 20' = 5' max. offset allowed
This venting configuration meets requirements.
4" / 7" Venting
5" / 8" Venting
A - Termination
MVTK-1
PVTK-1
B - Flex Sections
MFL-1 (12" Section)
MFL-2 (24" Section)
MFL-3 (36" Section)
MFL-4 (48" Section)
PFL-1 (12" Section)
PFL-2 (24" Section)
PFL-3 (36" Section)
PFL-4 (48" Section)
C - Rigid Sections
MEXT-1 (12" m/f Section)
MEXT-2 (24" m/f Section)
MEXT-3 (36" m/f Section)
MEXT-4 (48" m/f Section)
PEXT-1 (12" m/f Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
D - Support Ring
& Plate
MSPXT-8
PSPXT-8
E - Firestop
FS-8
PS-8
F - Roof Flashing
MRF-7 (1/12 - 7/12 pt.)
MRF-12 (7/12 - 12/12 pt.)
PRF-7 (1/12 - 7/12 pt.)
PRF-7 (7/12 - 12/12 pt.)
G - Adaptor / Vent
Reducer
PVA5487 (5"/8" to 4"/7")
Figure 15.
Straight, vertical venting
showing required MXT-10/PXT-10
adaptor (supplied with the MVKT-1/PVTK-1 termination).
MEXT/PEXT
MEXT/PEXT
MXT-10/PXT-10
45”
Min.
2’ max. 4”/7”
6’ max. 5”/8”