25
Installation
XG0207 - 170223
Section 6: Finishing
Mantels & Surrounds
Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown
Fireplace Facing
When sizing the finish material for your fireplace, it is important to
remember the following: THE OPENING MUST NOT BE OBSTRUCTED IN
ANY WAY - to do so restricts the air supply for the control compartments
and heat exchanger it also prevents access for servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint.
Finishing around the fireplace
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
Please be aware, temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
NOTE:
UNIT CANNOT BE RECESSED INTO A WALL
Side wall clearances are 3". Combustible surrounds may be installed
with 3" clearance to the side of the fireplace as shown.
6”
6”
3
”
Flush Finishing the Fireplace
A noncombustible finishing material may be installed over the face of
the unit as shown below. Please be aware that the temperature of the
fireplace face will be extremely hot and could be subject to cracking in
seams of concrete board or tile installed directly on the face.
Please refer to the flush face finishing guide for more detailed
instructions.
Figure 21.ddd
Flush facing vs Standard vs High style
HIGH STYLE FINISHING
STANDARD FINISHING
FLUSH FACE FINISHING
(PREFERRED STYLE)
H38ST COMBUSTIBLE MANTLES AND FACINGS (FLUSH FINISH)
H42ST COMBUSTIBLE MANTLES AND FACINGS (FLUSH FINISH)
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
0
0
11
11
12
12
1
1
5
5
11
11
15
15
2
2
6
6
12
12
16
16
3
3
9
9
7
7
13
13
17
17
4
4
10
10
8
8
14
14
Vertical Height (In.)
Vertical Height (In.)
Horizontal Run (In.)
Horizontal Run (In.)
Non-combustible
facing
Non-combustible
facing
Nailing flange or
equivelent
Non-combustible
facing
Top of glass
Top of glass
Combustible facing material
Combustible facing material
Combustible facing material
Non-combustible facing
material
Combustible header
Combustible construction
allowed in shaded area
Combustible construction
allowed in shaded area
STEEL STUD
CONSTRUCTION
ALLOWED WITHIN GREY
SLASHED AREA
STEEL STUD
CONSTRUCTION
ALLOWED WITHIN GREY
SLASHED AREA
Figure 21.b
Combustible mantles and facings. (Not to scale)
Figure 21.b
Combustible mantles and facings. (Not to scale)