Page 6
H42DF-O Outdoor Gas Fireplace
Part No. XG0149
Installation
Installing Terminations with Built-In Frames
Installing Terminations with MSR Frames
12
12
1. Frame the termination opening to 12" x 12".
2. Fasten the termination to the studs using a minimum of 4 screws.
11
11
1. Frame the termination opening to 11" x 11".
2. Fasten the termination to the studs using a minimum of 4
screws.
Installing Terminations with MOSR Frames
12
12
12
MOSR
1. Frame the termination opening to 12" x 12".
2. Fasten the MOSR frame to the interior side of the studs using a
minimum of 4 screws.
3. Insert the termination into the MOSR frame as shown here, and
attach by screwing through the four pilot holes in the termination.
MSR
MTO-3 (4"/7")
PTO-3 (5"/8")
MTO-3F (4"/7")
PTO-3F (5"/8")
MTO-3 (4"/7")
PTO-3 (5"/8")
MTKOG
(4"/7")
PTKOG
(5"/8")
1. Ensure that the two
long
mounting brackets are facing the bottom
of the termination. (See inset). This will provide more heat protection
at the top of the termination, where temperatures are highest.
2. Attach to the faceplate of the termination using four sheet metal
screws.
Installing Heat Guards over Terminations
Installing The Remote Switch
The
H42DF-O'
s gas valve, located behind the lower trim, may be
connected to a wall switch. The valve generates its own power on
a
millivolt circuit. Use only low voltage wire, and DO NOT
connect
any external power to it.
Refer to Figure 26 for wiring requirements.
Note:
The switch location must not exceed 30' from the fireplace.
Installing The Standoffs
To avoid elevated mantel temperatures, all H42DF-O gas
fireplaces are required to have the supplied standoffs installed.
The fireplace is supplied with two standoffs. Bend and install these
standoffs on top of the fireplace ensuring that the height of the standoff
maintains a 6" clearance.
Figure 6b.
Installing the standoff's.
Installing the Nailing Flange
Extension
Once the fireplace is placed into the framed opening, the supplied
nailing extension must be placed along the top edge of the fireplace,
and nailed in place to the framing, as illustrated below.
Figure 6c.