Page 10
H42DF-O Outdoor Gas Fireplace
Part No. XG0149
Installation
Example:
Typical vent installation.
20' vertical vent
2 - 2' offsets required
25% of 20' = 5' max. offset allowed
This venting configuration meets requirements.
4" / 7" Venting
5" / 8" Venting
A - Termination
MVTK-1
PVTK-1
B - Flex Sections
MFL-1 (12" Section)
MFL-2 (24" Section)
MFL-3 (36" Section)
MFL-4 (48" Section)
PFL-1 (12" Section)
PFL-2 (24" Section)
PFL-3 (36" Section)
PFL-4 (48" Section)
C - Rigid Sections MEXT-1 (12" m/f Section)
MEXT-2 (24" m/f Section)
MEXT-3 (36" m/f Section)
MEXT-4 (48" m/f Section)
PEXT-1 (12" m/f Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
D - Support Ring
& Plate
MSPXT-8
PSPXT-8
E - Firestop
FS-8
PS-8
F - Roof Flashing MRF-7 (1/12 - 7/12 pt.)
MRF-12 (7/12 - 12/12 pt.)
PRF-7 (1/12 - 7/12 pt.)
PRF-7 (7/12 - 12/12 pt.)
G - Adaptor / Vent
Reducer
PVA5487 (5"/8" to 4"/7")
Figure 15.
Straight, vertical venting
showing required MXT-10/PXT-10
adaptor (supplied with the MVKT-1/PVTK-1 termination).
MEXT/PEXT
MEXT/PEXT
MXT-10/PXT-10
Figure 17.
Vertical venting with 2 offsets (1 offset= two
90° bends).
Figure 16.
Vertical venting with 1 offset (1 offset= two
90° bends).
* Minimum 1-1/2" clearance to combustibles
* Minimum 1-1/2" clearance to combustibles