EDVWSPV Horizontal Power Vent System

Part No. XG1303 - 120110

Introduction

     CAUTION!

Due  to  its  high  operating  temperatures,  the  appliance 

should  be located in a well ventilated area / space. See 

the clearancespecifications on Page 8.

  Children and adults should be alerted to the hazards 

of the high surface temperature, which could cause 

burns or clothing ignition.

  Young children should be carefully supervised when 

they are in the same room as the appliance.

  Clothing or other flammable materials should not be 

placed on or near the appliance.

Before You Begin

■ Minimum clearances 1” from vent to all combustible materials 

must be maintained. Clearances listed in the fireplace’s Instal-

lation Operation and Maintenance Instructions supersede this 

number.

CAUTION

:

Ensure Perforated Air Holes in the New Pipe Adapter / Restrictor 

are not Covered when installing New Pipe Connection.

CAUTION

:

When cold air enters the warmer building interior, primarily at the 

air intake end, condensation may occur on the exterior of the flex 

pipe.  To limit this condensation, install insulation over the last 

twenty feet of flex pipe. Also, by sloping the last 20'-0" feet of flex 

pipe downward toward the exterior of the building, elimination of 

most of the condensation problems should occur. Ensure the ter-

mination is securely fastened, and sealed to the flex pipe. Fasten 

the termination to exterior of the building with water tight sealant 

and the appropriate fasteners.

General Information

This installation guide covers installation of the External Power Vent 

System only. This system is designed to allow installation of gas fire-

places that cannot be done with a standard Direct Vent gas fireplace 

installation.
Also, read through the fireplace's Installation Operation and Mainte-

nance Instructions, as it must also be adhered to.
 

 

Power Cord Harnesses:

 

EPVH10 -10 foot power cord and harness

 

EPVH20 -20 foot power cord and harness

 

EPVH30 -30 foot power cord and harness

 

EPVH40 -40 foot power cord and harness

 

EPVH50 -50 foot power cord and harness

 

EPVH60 -60 foot power cord and harness

 

EPVH70 -70 foot power cord and harness

 

EPVH80 -80 foot power cord and harness

 

EPVH90 -90 foot power cord and harness

 

EPVH100 -100 foot power cord and harness 

Selecting and Installing the 

Fireplace

When selecting a gas fireplace for use with the External Power Vent 

System, take into consideration the various requirements and limita-

tions in the 

venting installation section

 for the following models: 

Models Equipped with Hot Surface Ignition (HSI)

It is recommended that this system be used with a gas fireplace 

equipped with a Hot Surface Ignition System. Because there is not a 

pilot in this system, there is more flexibilty on venting requirements. 

For example  downward vertical vet runs are possible with an HSI 

system, as outlined in the 

Venting Section.

Models Equipped with Millivolt/ Standing Pilot

If a standing pilot model must be used, then the 

millivot wiring har-

ness 

must be installed, see the 

Wiring Section 

for more information. 

Also, downward vertical vet runs are not possible with a standing pilot 

system, as outlined in the 

Venting Section.

Summary of Contents for EDVWSPV47

Page 1: ...ce has been turned off Safety screens are available and can reduce the risks of severe burns Please keep children away from the fireplace at all times Warning Improperinstallation adjustment alteration serviceormaintenancecancause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to ...

Page 2: ...ddress practices not related to personal injury Table Of Contents Important All dimensions and design specifications are subject to approval upon quotation of fire place and associated equipment Congratulations Safety Alert Key Table of Contents 2 Specifications 2 Introduction 3 Dimensions 4 5 Installation General Information 6 Selecting and Installing the Fireplace 6 Vent Installation 6 Power Ven...

Page 3: ...l Information This installation guide covers installation of the External Power Vent System only This system is designed to allow installation of gas fire places that cannot be done with a standard Direct Vent gas fireplace installation Also read through the fireplace s Installation Operation and Mainte nance Instructions as it must also be adhered to Power Cord Harnesses EPVH10 10 foot power cord...

Page 4: ...Power Vent System Part No XG1303 120110 Dimensions 9 3 4 REF 11 1 16 11 1 16 9 3 4 10 9 16 4 9 0 Dimensions EDVWSPV47 Dimensions EPVF47 mounting frame for EDVWSPV47 14 1 4 14 1 16 12 1 8 1 1 2 7 9 11 16 4 9 16 12 5 16 4 9 11 16 ...

Page 5: ...Vent System Part No XG1303 120110 9 3 4 10 9 16 5 9 0 11 1 16 11 1 16 11 1 16 10 9 16 5 9 0 Dimensions Dimensions EDVWSPV58 Dimensions EPVF58 mounting frame for EDVWSPV58 14 1 4 14 1 16 1 1 2 4 9 16 8 12 1 8 9 11 16 12 5 16 4 9 11 16 ...

Page 6: ...installations are only possible with gas fireplaces equipped with Electronic or Hot Surface Ignition HSI H V Elbow 1 Elbow 2 Elbow 3 Elbow 5 Elbow 4 Elbow 6 H3 H2 H1 V1 V2 V3 H2 H1 V D Installing the Power Vent Figure 4 Framing the Opening for Power Vent Selecting A Termination Location Before installing the termination ensure that the proper air flow restrictor is installed as shown on page 5 and...

Page 7: ...embled Rough in Kit Step 7 Fasten Conduit mounting frame into place using existing hard ware 6 pcs Coil conduit in behind cover Step 8 Install the Power Vent Power communication harness Hold the Power Vent in close proximity of the assembled Rough in Kit and plug in the Power Vent communication Power Cord Note the direction and orientation of the pins inside the Power Vent connector snap together ...

Page 8: ...nd it must be at least 1 clear of all venting 1 min Vent Cable Figure 12 Wiring Diagram for Power Vent System Control Cable Installation for Vertical Termination EXPVH 10 100 Honeywell SV9501M PPO Box Power Vent EDVRP47 PVFCB ECB005 Pilot Inside Fireplace Wall Switch 120V Step 10 Completed installation Step 9 Install the Power Vent Place the Power Vent into the Rough in frame aligning the Power Ve...

Page 9: ...m Part No XG1303 120110 Installation WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Figure 13 Standard ECB006 Wiring Schematic for Power Vent System ...

Page 10: ...ected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Wa...

Page 11: ...ce to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearance under veranda porch deck or balcony 30 inches 75 cm minimum to n...

Page 12: ...12 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 EDVWSPV58 Horizontal Power Vent Detail Front View 30 Min 30 Min Eaves Overhang Wall F G H I 30 75cm Min V Appendix A Termination Locations cont d ...

Page 13: ... directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon in...

Page 14: ...Page 14 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 Notes ...

Page 15: ...Page 15 EDVWSPV Horizontal Power Vent System Part No XG1303 120110 Notes ...

Page 16: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG1303 062010 f i r e f e a t u r e www montigo com ...

Reviews: