9
Installation
xg0226 - 042220
clearances
MODEL
Top - Top
vent
†
Rear
Sides
Floor
Mantel
vent Pipe
drl**3613*i
21"
2"
1"
0"
6"
1'' all around
2" on the
horizontal
DRL**4813*I
21"
2"
1"
0"
6"
1'' all around
2" on the
horizontal
NOTES:
†
Clearance from top of fireplace to a ceiling within the fireplace
enclosure.
Figure 4.
Combustible Wall Clearances
When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to:
Section 3: venting
Montigo offers a variety of direct venting and termination options. The
direct vent termination location Must be selected such that it is the
highest point in the venting assembly. it should also be selected such
that it provides the shortest vent run possible. should it be impossible
to ensure that the termination is the highest point or to meet the
venting guidelines laid out below please contact your Montigo dealer
to discuss power venting options.
Notes For Planning venting:
•
Venting originates from the top of the unit
•
Venting can terminate through the roof or through an exterior wall.
•
refer to Appendix A - termination locations to ensure the planned
termination location is acceptable.
• Once the termination location has been established, refer to the
appropriate section below for installation details
• All fireplaces shipped from the factory are top vent.
•
Silicone
application is
NOT
required when joining Montigo vent
pipes and components.
Under no circumstances can Montigo flex venting be cut to
accommodate an installation. use an alternative length to complete
your vent run. (Excluding flex included in the MVK05)
notice
MFvK05
MFVK05 Flex Vent Kit is a standalone 5 ft. vent kit that cannot
be combined with Montigo Flex or Montigo rigid pipe to extend
beyond the 5ft of flex included in this kit. The Flex in this kit
can be cut down if shortening is required. Any other venting
configuration beyond the 5ft included in the MVK05 kit will
require going to either Montigo rigid pipe or Montigo Flex pipe
referenced in the manual pages Venting section.
Figure 4.a
MFVK05 Flex Vent Kit