background image

4

© 2018 Monte Carlo Fan Company

10/2018

7

8

10

11

12

9

Install ball end of downrod into mounting 

bracket opening. Align (engage) slot on 

ball with tab on mounting bracket.

Warning:

 Failure to align slot on ball with 

tab may result in serious injury.

Important

: If using the angle mount, 

make sure open end of mounting bracket 

is installed facing the higher point of the 

ceiling and make sure the ceiling angle is 

not steeper than 30º. 

For Canadian installation and for USA fan 

and light kit combinations over 35 lbs, in 

both flush and downrod modes the safety 

cable must be installed into the house 

structure beams using 3” lag screws, 

washers and lock washers provided. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

  

Make wiring connections using wire 

connectors provided as indicated above.    

Connect Black wire from fan to Black 

(Live) wire from house. Connect White 

wire from Fan to White (Neutral) wire from 

house. Connect all green grounded wires 

to Grounded wire from House. Make sure 

that no filaments are outside of the wire 

connectors.

After making the wire connections, the wires 

should be spread apart with the grounded 

conductor and the equipment-grounding 

conductor on one side of the outlet box and 

ungrounded conductor on the other side of 

the outlet box. The splices after being made 

should be turned upward and pushed carefully 

up into the outlet box.              

Lift Canopy, allowing the 2 studs to 

protrude through the canopy.  

Install knurled nuts provided and tighten 

the knurled nuts securely. The canopy 

should adjust for any irregularity in the 

ceiling or outlet box.

Make sure the studs protruding from the 

bottom of the Mounting bracket are 

installed with threads all the way through 

the bracket. 

Insert blade into the slot on flywheel.

Install blade with a blade supporting plate 

by the screws provided, aligning each of 

the holes as shown and tighten all screws 

securely. Repeat this process for 

remaining blades.

Tab

Slot

Stud

SAFETY CABLE INSTALLATION

Lag screw

Safety cable

Washer

Lock washer

Grounded

wires

Ungrounded

wires

Blade

Blade supporting plate

Power supply

Black

white (Neutral)

Gr

ounding/Gr

een

Black (Live)

W

all switch

Summary of Contents for 5VMR84 D Series

Page 1: ...DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5VMR84XXXD Series Fan cETL Model NO 5VMR84XXXD 9 7 kgs 21 4 lbs ...

Page 2: ...x to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan should only be used with ...

Page 3: ...g member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws securely Remove shipping stabilizers from motor Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cross pin and keeper pin from downrod Place do...

Page 4: ... from Fan to White Neutral wire from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splic...

Page 5: ...llustration Keep screws Install blanking plate onto light plate using the set screws of light shade which were just removed Isolate the quick connects with electrical tape Attach blanking plate assembly onto light pan by locating dimples in light pan with grooves in blanking plate and twist clockwise until tight Attach light pan onto the plate on motor Place light pan over the lead wires from fan ...

Page 6: ...ery Duracell MN21 Evereday A23 GP 23A all 12V Note If not using for long periods of time remove battery to prevent damage to remote transmitter and store the remote transmitter away from excess heat or humidity Set change the dip switch position on the transmitter to desired code setting If you have more than one fan in your house and you don t want them to be controlled by the same transmitter yo...

Page 7: ...and power on it is because your fan is still memorize the previous setting at factory Make Remote control setting learn function and your fan will be ready for use 2 If fan or light isn t working reset power turn the power off for at least 5 seconds and then turn the power back and redo the remote setting 3 It is not available to separately operate the remote setting for more than one fan in the s...

Page 8: ...plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat fo...

Page 9: ...Nov 2018 ...

Reviews: