  Trouble Shooting

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, 

installation, please call our Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be 

locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION

either way. Fan will not operate when switch is in the middle.

4.If this fan uses remote controller, make sure dip switches are setting properly and make 

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each 

other or against the interior wall of the switch housing.

CAUTION

4.Check to be sure light bulb is tight in socket and not touching the glass shade.

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  

6.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear 

after this period.

1.If this is a downrod mount fan, make sure the ridge on mounting bracket engages the 

notch in the downrod ball.

2.Make sure that canopy, mounting bracket or mounting plate are tightened securely to 

4.Check that all blade holders are tightened securely to motor.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by 

selecting a point on the ceiling above the tip of one of the blades. Measure this distance 

from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade 

is positioned for measurement. Repeat for each blade. If all blade levels are not equal, 

you can adjust blade levels by the following procedure. To adjust a blade tip down, insert 

a washer (not supplied) between the blade and blade holder at the screw closest to the 

motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade 

holder at the two screws farthest from the motor. Reverse the position of the washer if 

blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can 

redistribute the weight and possibly result in smoother operation.

If the above steps do not eliminate the wobble problem, you will need to dynamic balance 

your fan with balancing kit provided.    

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulb and make sure bulb is tight in socket.

5.Remove light kit and check the plug connections if they are present.

6.If this fan uses remote controller, make sure dip switches are setting properly and make 

 

CAUTION

: Make sure main power is turned off before entering switch housing and/or 

canopy.

                                       

                               

2. If fan sounds noisy:

3. If fan wobbles:

4. If light does not work:

1. If fan does not start:

Trouble

Suggested Remedy

Summary of Contents for 5VMR84 D Series

Page 1: ...DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5VMR84XXXD Series Fan cETL Model NO 5VMR84XXXD 9 7 kgs 21 4 lbs ...

Page 2: ...x to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan should only be used with ...

Page 3: ...g member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws securely Remove shipping stabilizers from motor Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cross pin and keeper pin from downrod Place do...

Page 4: ... from Fan to White Neutral wire from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splic...

Page 5: ...llustration Keep screws Install blanking plate onto light plate using the set screws of light shade which were just removed Isolate the quick connects with electrical tape Attach blanking plate assembly onto light pan by locating dimples in light pan with grooves in blanking plate and twist clockwise until tight Attach light pan onto the plate on motor Place light pan over the lead wires from fan ...

Page 6: ...ery Duracell MN21 Evereday A23 GP 23A all 12V Note If not using for long periods of time remove battery to prevent damage to remote transmitter and store the remote transmitter away from excess heat or humidity Set change the dip switch position on the transmitter to desired code setting If you have more than one fan in your house and you don t want them to be controlled by the same transmitter yo...

Page 7: ...and power on it is because your fan is still memorize the previous setting at factory Make Remote control setting learn function and your fan will be ready for use 2 If fan or light isn t working reset power turn the power off for at least 5 seconds and then turn the power back and redo the remote setting 3 It is not available to separately operate the remote setting for more than one fan in the s...

Page 8: ...plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat fo...

Page 9: ...Nov 2018 ...

Reviews: