Loosen 3 screws with k ey slots and remove the

screwwithout key slot. 

19

Take plate and place o ver the 3 screws with k ey

slots  and twist to hold in place. R eplace the

screw removed and tighten all 4 screws secure -

ly holding the plate.

20

Plug white wire from fan to white wire  from

light kit. Then plug bl

ack

 from fan to black from

light kit.

21

Attach glass by locating dimples in light kit and

aligning it with the gro ves in glass and twisting

clockwise till tight.

24

Install the 2 X 50 w att halogen bulbs. Do not

touch bulb surface as oily residue from skin can

cause the bulb to explode. Bulbs included.

WARNING: Over lamping the fan will
result in the fan lights shutting down
until the proper wattage of bulbs are
installed. Reset the lights by turning off
the wall switch, breaker,or by remote.
Replace bulbs with the correct wattage
bulbs, turn the power on.

23

If you choose not to use light kit. Loosen 3

screws with key slots and remove the 1 without

slots.  Attach switch cap holder b y placing over

screws and twisting clockwise into place.

Replace screws removed and tighen all screws

securely. Place switch cap co ver over switch cap

holder and tighen screw to hold in place.

25

Remove cover by snaping off from top or bot -

tom. Remove battery cover. Install 12V battery

into wall remote. Duracell MN21 / Eveready

A23 / GP 23A all 12V.Attach cover of remote by

placing over buttons and snap the battery

cover in place.

Place face plate over battery compartment and

buttons. Place remote over 2 pins on front co ver.

Attach cover of remote by placing over 4 pins

and snaping into place.

27

26

HAND HELD INSTALL

Install wall control unit to outlet bo x

using machine screws provided.

28

Attach front cover to wall control

with screws provided. Snap battery

cover in place. 

29

WALL MOUNT INSTALL

Loosen 2 screws and remove 1 screw from light

pan. Save screw for later use. 

Attach light fixture by aligning keyhole slots on

light fixture with screws on light pan and twist

clockwise till lock. Re-install the screw removed.

Tighten all screws securely.   

22

Summary of Contents for 5MMR54 D-L Series

Page 1: ...Owner s Manual Ceiling Fan Installation Instructions For 5MMR54XXD L Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light 5MMR54 CUL ENG 092010 ...

Page 2: ...r a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA an...

Page 3: ... The screws w ashers and motor pads are pre installed to the blade hold ers Attach blade assembly to motor and tight en screws securely 18 Align hole in downrod with hole in y oke and install cross pin 8 Tighten 2 downrod set screws and lock nuts 10 Make wire connections as per abo ve diagram Connect the white wire from the fan to the White or Neutral wire from the power source Connect the black w...

Page 4: ...h key slots and remove the 1 without slots Attach switch cap holder by placing over screws and twisting clockwise into place Replace screws removed and tighen all screws securely Place switch cap cover over switch cap holder and tighen screw to hold in place 25 Remove cover by snaping off from top or bot tom Remove battery cover Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23...

Page 5: ...right to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fanmust be running to reverse UPLIGHT ON OFF SET TING AND DIMMER Press...

Page 6: ...supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side b y side blades can redistribute the weight and possib...

Page 7: ...Instructions pour l installation d un ventilateur de plafond Por 5MMR54XXD L Ventilateurs LIRE ET GARDER CES INSTRUCTIONS Poids total du ventilateur et du kit d éclairage manuel de l utilisateur ...

Page 8: ...e 14 Le débit en air de combustion requis pour le fonctionnement en toute sécurité d équipements alimentés par du combustible peut être affecté par la mise en marche de cette unité Suivre les directiv es et appliquer les normes de sécurité indiquées par le fabricant d un tel équipement comme celles communiquées par l Association Nationale de la Protection contre les Incendies NFP A et par les Ingé...

Page 9: ...qu aucun filament ne dépasse des capu chons électriques Après avoir établi les liaisons électriques vous devez étaler les fils en mettant le conducteur mis à la masse et le conducteur de mise à la terre de l appareillage d un côté du boîtier de sortie de courant et le conducteur non mis à la terre de l autre côté de la boîte de sortie de courant Raccorder les fils conformément au schéma précédent ...

Page 10: ...ire Desserrer les 3 vis à rainure de clavette et déposer les deux vis sans rainure Monter le boîtier du commutateur en le plaçant au dessus des vis et le tourner dans le sens horaire pour le fixer en place Revisser les vis déposées et bien serrer toutes les vis Placer le cou vercle du boîtier de commutateur par dessus le boîtier et serrer la vis pour le fix er en place 25 26 Enlever le couvercle e...

Page 11: ... que le bouton soit libéré La lumière maintiendra pour la dernière fois le réglage si arrêtée Expédiez inverse enfoncent le bouton de tour accordent quelques secondes pour que l extérieur change la direction de rotation avec le fonctionnement de ventilateur À GRANDE VITESSE VITESSE MOYENNE À VITESSE RÉDUITE ÉVENTEZ OUTRE DU RÉGLAGE ventila teur de tours au loin seulement ÉVENTEZ L INVERSE la press...

Page 12: ...uits associés à un nouv eau ventilateur disparaissent généralement après cette période 1 Assurez vous que la nervure de la garniture s engage dans l encoche de la rotule de la tige v er ticale 2 Assurez vous que toutes les lames sont vissées fermement sur les porte pales 3 Assurez vous que tous les porte pales sont solidement fixés au moteur 4 Assurez vous que la garniture et le support de suspens...

Reviews: