background image

© 2011 Monte Carlo Fan Company

5/10/2012

2

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA
70-1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be
turned upward and pushed carefully up into the outlet box.

WARNING

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.

WARNING

: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION: 

For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Re-

move Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to
the building structure (or the ceiling joist).

WARNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do

not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING: 

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed

control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION

: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

Note:

Suitable for use in damp location.

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,

Stepladder and Wire Strippers.

Summary of Contents for 5GIR54XXD-L Series

Page 1: ...ard and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5GIR54XXD L Series Fan Total fan weight with light kit UL Model No AG 523OD 12 49 kgs 27 48 lbs ...

Page 2: ...s Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade hol...

Page 3: ... 2011 Monte Carlo Fan Company 5 10 2012 3 For Downrod Mount go to step 7 For Downrod Mount go to step 7 For Flush Mount go to step 18 For Flush Mount go to step 18 ...

Page 4: ... is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box 11 Safety cable installation safety cable lag screw safety cable 3 lag screw lock washer washer Next lift the cover ring and install knurled nuts as shown Tighten the knurled nuts securely Th...

Page 5: ...lo Fan Company 5 10 2012 5 Install 2 of the screws provided to the side panel corresponding to the open slotted holes on the canopy upper ring Remove the all thread studs from the lower part of the mounting bracket 22 ...

Page 6: ...delabra bulbs Bulbs included WARNING Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed Reset the lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 32 ...

Page 7: ... 2011 Monte Carlo Fan Company 5 10 2012 7 Reverse function for this fan is a switch on top housing of the fan body Turn fan off and flip switch this will reverse the direction of the blades 39 ...

Page 8: ...emote controls or light dimmers LIGHT ON OFF To turn light on press light button once quickly To turn off press once quickly while light is on FAN SPEED Depress 1 dot for low speed 2 dots for medium or 3 dots for high To turn fan off press square HIGH SPEED MEDIUM SPEED LED LIGHT LOW SPEED LIGHT ON OFF SETTING Press to turn on off light FA N O F F S E TT I N G Turns fan off only ...

Page 9: ... not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a w asher not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the w asher if blades mount from top of blade 6 If blad...

Page 10: ......

Reviews: