COOK-N-HOLD MODELS (IE; SEK15AH AND SEK2=15AH--FIG. 3)
1. KEY PAD CONTROLS .
IN ADDITION TO THE KEYS STANDARD WITH THE
PROGRAMMABLE MODE, COOK-N-HOLD MODELS INCLUDE COOK-HI-FAN AND ROAST-LOW-
FAN KEYS WITH WHICH TO CHANGE THE FAN SPEED. THERE IS ALSO A HOLD KEY WHICH
ALLOWS A HOLD TEMPERATURE TO
BE
MANUALLY SET OR PROGRAMMED INTO MEMORY.
OPERATIONAL DESCRIPTION
POWER UP (ALL MODELS)
ON INITIAL POWER UP THE TIME DIGITS WILL ALWAYS DISPLAY ZERO WITH COLON.
THE TEMPERATURE DIGITS WILL DISPLAY ZEROS WITH THE DEGREES INDICATOR
LIGHTED. THE "C" ANNUNCIATOR WILL ALSO BE LIT IF THE C OPTION IS
SELECTED. SUBSEQUENT POWER UPS WILL RESULT IN THE TEMPERATURE TIMER DIGITS
DISPLAYING THE PREVIOUS SET TIME AND TEMPERATURE WHEN POWER WAS REMOVED
FROM THE CONTROL.
MANUAL TEMPERATURE SELECTION AND OPERATION (ALL MODELS)
ROTATING THE TEMPERATURE DIAL CLOCKWISE WILL INCREMENT TEMPERATURE DIGITS
IN THE DISPLAY IN 5 F OR 1 C INCREMENTS. THE OVEN WILL START HEATING AS
SOON AS THE SET TEMPERATURE IS HIGHER THAN THE OVEN TEMPERATURE. THE
COOK ANNUNCIATOR WILL COME ON AND THE HIGH SPEED FAN WILL ENERGIZE WHEN THE
TEMPERATURE IS SET TO ANY NON-ZERO VALUE. THE TEMPERATURE DIGITS WILL
DISPLAY THE SET TEMPERATURE FLASHING AT AN APPROXIMATE 1-SECOND RATE
UNTIL THE OVEN REACHES SET TEMPERATURE. UPON REACHING SET TEMPERATURE THESE
DIGITS WILL BECOME STATIC. IF THE SET TEMP IS SET TO THE SAME TEMP
AS THE ACTUAL TEMP OF THE OVEN, THE DISPLAY WILL NOT FLASH.
ASSUMING A NEW SET TEMPERATURE IS ENTERED, WHICH IS LOWER THAN THE PREVIOUS
SETTING, THE NEW SET TEMPERATURE WILL FLASH UNTIL THE OVEN TEMPERATURE
HAS COASTED DOWN TO THIS NEW SETTING AND WILL THEN BECOME STATIC.
MEASURED OVEN TEMPERATURE CAN BE RECALLED BY PRESSING THE TEMP KEY. MEASURED
TEMPERATURE WILL BE DISPLAYED AS LONG AS THE KEY IS PRESSED. UPON RELEASE
THE DISPLAY WILL REVERT TO DISPLAYING THE SET TEMPERATURE.
TO TURN THE OVEN OFF WITHOUT POWERING THE CONTROL DOWN THE
TEMPERATURE DIALS CAN BE ROTATED COUNTER-CLOCKWISE UNTIL ZERO DEGREES ARE
SHOWN IN THE DISPLAY.
MANUAL TIME SELECTION AND OPERATION (ALL MODELS)
ROTATING THE TIMER SWITCH CLOCKWISE WILL INCREMENT THE TIME DIGITS-IN THE
DISPLAY IN THE FOLLOWING MANNERS
-1 MINUTE INCREMENTS UP TO ONE HOUR
-5 MINUTE INCREMENTS UP TO TWO HOURS
-10 MINUTE INCREMENTS UP TO TWELVE HOURS.
THE HR ANNUNCIATOR IS TO BE LIGHTED AT ALL THE TIMES IF THE
MINUTES/HOURS MODE IS SELECTED. THE MAXIMUM TIME ENTRY ALLOWABLE WILL BE
TWENTY-FOUR HOURS. COUNTERCLOCKWISE ROTATION OF THE ROTARY SWITCH WILL
DECREMENT THE COUNTER IN A LIKE MANNER. THE TIMER COUNT DOWN IS STARTED
BY MOMENTARILY PRESSING THE START/TIMER SWITCH. IF THE TIMER IS SET AND NOT
STARTED, THE TIME DIGITS AND THE COLON FLASH AT A ONE-CYCLE PER SECOND RATE.
ONCE STARTED, THE TIMER DIGITS BECOME STATIC BUT THE COLON REMAINS FLASHING.
WHEN THE TIMER REACHES ZERO, A REPEATING BEEP