MTLB-V1-051506
Page
4 of 5
Copyright 2002-2006, Monster Tower, Inc
Wiring Recommendations
We recommend using a SPST relay (Single Pole Single Throw) with your switch and appropriate
gauge wiring. Relays are readily available at auto parts stores.
Not using a relay could cause excessive heat in the wiring and switch and create a risk of fire
because of the amount of power being drawn by the high output lights. A relay works by using a
switch to run 12 volts to the relay. The relay acts as an electrical switch that activates and draws
power straight from the battery connection and sends it to the lights or accessory. The power
actually going to the switch never gets routed to the lights.
See diagrams and wiring size chart at the end of this document for options & details.
Running Wires Through The Tower
The following is specific to running wires on a Monster Tower, otherwise consult your tower
installation manual or provider for instructions on running wire inside your tower.
When you add speakers or lights to your Monster Tower, you can hide the wires inside of the rear
legs of the tower as well as in the straight cross member of the top section. Since the mating
parts insert ½” inside each end of the rear leg you can drill 1” away from the weld lines. For the
top section cross member you will need to place the hole 3” from the weld line to clear the
rotating collar assembly. The hole size will depend on what size wire you are running and how
many items you need to wire. The maximum hole size we recommend is ½” but normally smaller
is all that is needed.
We recommend covering the exposed wiring with 3/8” or 1/2” wiring loom and electrical tape for a
professional, watertight appearance.
½”
1”
Summary of Contents for Light Bar
Page 10: ......