Do not operate this device when the ambient temperature exceeds 
+104°F (+40°C). 

 

Ensure that there is sufficient ventilation to allow the unit to cool. Do 
not block any ventilation vents or slots and ensure that there are no 
flammable materials or adjacent surfaces within 20 inches of this 
device. 

 

Prior to operation, check the unit and power cord for physical 
damage. Do not use if physical damage has occurred. 

 

Before plugging the unit into a power outlet, ensure that the outlet 
provides the same type and level of power required by the device. 

 

This device uses a grounded power cord and requires a ground 
connection for safe operation. Ensure that the power source has a 
proper ground connection. Do not modify the plug or use a "cheater" 
plug to bypass the ground connection. 

 

Unplug this device from the power source when not in use. 

 

Never unplug the unit by pulling on the power cord. Always grasp 
the connector head or adapter body. 

 

Take care to prevent damage to the power cord. Do not allow it to 
become crimped, pinched, walked on, or become tangled with other 
cords. Ensure that the power cord does not present a tripping hazard. 

 

Clean using a soft, dry cloth only. Do not use chemical cleaners, 
solvents, or detergents. For stubborn deposits, moisten the cloth 
with warm water. 

 

This device has no user serviceable parts. Do not attempt to open, 
service, or modify this device. 

 

Avoid direct eye exposure to the light from this device. Do not look 
directly into the light source. 

 

 

Summary of Contents for 612760

Page 1: ...MONOPRICE SoftStage 150 Watt COB LED Stage PAR RGB P N 612760 User s Manual ...

Page 2: ... 6 SAMPLE WIRING DIAGRAM 6 DMX TERMINATION 7 CONTROLS AND MENU DISPLAY 7 MENU MAP 8 nodE FUNCTION 9 PRESETS 9 MASTER SLAVE MODE 9 DMX CONTROL 10 3CH MODE 10 6CH MODE 10 7 8CH MODE 11 TROUBLESHOOTING 14 TECHNICAL SUPPORT 14 SPECIFICATIONS 15 REGULATORY COMPLIANCE 16 Notice for FCC 16 Notice for Industry Canada 16 ...

Page 3: ...Always secure the device to the mount using a safety wire or chain sufficiently robust to bear the weight of the device Do not subject the product to extreme force shock or fluctuations in temperature or humidity Do not touch the device the power cord or any other connected cables with wet hands Do not expose this device to excessively high temperatures Do not place it in on or near heat sources s...

Page 4: ...ion Ensure that the power source has a proper ground connection Do not modify the plug or use a cheater plug to bypass the ground connection Unplug this device from the power source when not in use Never unplug the unit by pulling on the power cord Always grasp the connector head or adapter body Take care to prevent damage to the power cord Do not allow it to become crimped pinched walked on or be...

Page 5: ...ce is second to none If you have any problem with your order please give us an opportunity to make it right You can contact a Monoprice Customer Service representative through the Live Chat link on our website www monoprice com during normal business hours Mon Fri 5am 7pm PT Sat Sun 9am 6pm PT or via email at support monoprice com PACKAGE CONTENTS Please take an inventory of the package contents t...

Page 6: ...DIMENSIONS DIAGRAM SAMPLE WIRING DIAGRAM Following is a sample wiring diagram for a multiple fixture installation Note that the final fixture must have a DMX Terminator plugged into the DMX Out connector ...

Page 7: ...ght is first plugged in the display will show the last DMX channel number set d001 by default Press the MENU button to access the menu system Press the ENTER button to edit the currently displayed mode Press the UP button to increase the value of the selected function or mode Press and hold the button to rapidly increase the displayed value The list will cycle back to the beginning after the maxim...

Page 8: ...splays the software version number nodE nod0 nod4 Speed limiter see the nodE section for details LEd on oFF LED display on auto off after 2 minutes of inactivity SoUA So UA Sound activation multicolor jump mode on off bL b000 b255 Blue dimming GL G000 G255 Green dimming rL r000 r255 Red dimming FLAS FL00 FL99 Strobe mode fast slow 00 No FX FAdE FA00 FA99 Color fade fast slow ASC AC00 AC99 Color ju...

Page 9: ...n 00 Red 08 Green Strobe 01 Green 09 Blue Strobe 02 Blue 10 Amber Strobe 03 Amber 11 Cyan Strobe 04 Cyan 12 Violet Strobe 05 Violet 13 White Strobe 06 White 14 RGB Color Jump 07 Red Strobe 15 Multicolor Jump MASTER SLAVE MODE Whenever the light is set to a mode other than a DMX address of Slave mode SL AU the fixture is in Master mode For example when set to Sound Activation mode So UA it is in Ma...

Page 10: ...he signals it can respond to correspond directly to the number of channels selected The following tables show the functions and values for each channel in the four different channel modes 3 6 7 and 8 3CH MODE CH VALUES FUNCTION PRIORITY REMARKS 1 000 255 Red dimming 0 100 2 000 255 Green dimming 0 100 3 000 255 Blue dimming 0 100 6CH MODE CH VALUES FUNCTION PRIORITY REMARKS 1 000 255 General dimmi...

Page 11: ...5 Bright Dark fade 096 127 Dark Bright Dark fade 128 159 Multicolor gradient 160 191 Multicolor fade in out 192 223 Multicolor jump 224 255 Sound Activated 7 8CH MODE CH VALUES FUNCTION PRIORITY REMARKS 1 000 255 General dimming 0 100 1 2 000 255 Red dimming 0 100 3 000 255 Green dimming 0 100 4 000 255 Blue dimming 0 100 5 000 014 Dimming 3 015 255 Strobe fast slow ...

Page 12: ... speed control 160 191 Multicolor fade in out 192 223 Multicolor jump 224 255 Sound Activated 7 000 009 Not used 2 Channel 1 is master dimmer Channels 2 4 have no effect 010 029 R 100 030 039 R 85 Y 15 040 049 R 60 Y 40 050 069 Y 100 070 079 Y 85 G 15 080 089 Y 60 G 40 090 109 G 100 110 119 G 85 B 15 120 129 G 60 B 40 130 149 B 100 150 159 B 85 C 15 160 169 B 60 C 40 170 189 C 100 190 199 C 50 P 5...

Page 13: ...nnel 8 note below table 006 055 DIMMING 0 056 105 DIMMING 1 106 155 DIMMING 2 156 205 DIMMING 3 206 255 DIMMING 4 Channel 8 Note Similar to the nodE setting but with variable speed control DIMMER0 has the fastest range DIMMER4 the slowest Depends on the use of channels 1 4 It is recommended to use DIMMING 1 at minimum if using a low res DMX controller ...

Page 14: ... that there is a DMX terminator connected to the DMX Out connector of the final fixture in the daisy chain Verify that the DMX controller is operating properly by using it with another DMX device TECHNICAL SUPPORT Monoprice is pleased to provide free live online technical support to assist you with any questions you may have about installation setup troubleshooting or product recommendations If yo...

Page 15: ...h Rate 1 5 kHz flicker free for TV and camera shooting Signal Input 3 pin XLR male Signal Output 3 pin XLR female Control Modes Standalone Master Slave Auto Sound Activated Functions Dimmer Strobe Jump Gradual Change Ingress Protection Rating IP20 Anti Electricity Intension 1 5kV Insulation Resistance 2MΩ Cooling Fan Dimensions 9 1 x 6 9 x 12 6 232 x 175 x 319 mm Weight 7 1 lbs 3 2kg ...

Page 16: ...protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferenc...