*The finished and rough-in dimensions are determined by the type
of installation being made. The finished cutout width includes
side panel thicknesses. See “Side Panel or Filler Options.”
Side View
(not to scale)
24 3/4"
4"
Front View
(not to scale)
42" Overall Width
41" Case Width
12 1/4" max
10-3/4" min
84 1/2" max
83" min
72 1/4"
*41 1/2" - 43 1/2"
7"
Wall View
(not to Scale)
Locate Grounded
Electrical outlet
Within Solid
Area Above
84 1/2" max
83" min
Finished
Rough
Opening
74"
From Floor to
Bottom of
Electrical Area
5"
18 3/8"
5"
3 1/2"
5"
3 1/2"
Locate Water
Supply Within
the Shaded
Area Below
ZIS42NY
42" Built-In Refrigerator (non-dispenser)
Design Information
Designed to be installed flush with surrounding cabinetry.
Cutout dimensions, clearances and side panel sizes are
determined by the many installation options available.
Side panels must be used whenever the sides of the
refrigerator will be exposed. If custom enclosure has
been made and installed, or if you are installing between
pantry and oven cabinets, side panels are not required
unless you are using frameless cabinets. IMPORTANT–
Side panels, 1/2" minimum thickness, are required when
using FRAMELESS CABINETS.
• Field installed custom panels or Lexan
panels are
required. The door panels and grille panel sizes vary to
accommodate the kit being used.
• A custom toekick can be installed to match or comple-
ment the surrounding cabinetry. A standard toekick is
supplied. If a custom toekick is to be installed, use the
supplied toekick as a template to cut out notches
around hinges and water lines.
Optional Kits:
• ZWBP42: Black Lexan
Panel Kit (no trim kit required).
• ZWWP42: White Lexan
Panel Kit (no trim kit required).
• ZWSP42: Stainless Steel Panel Kit (no trim kit required).
• ZKH1: Provides for the installation of a custom handle
on 1/4" custom panels.
• ZKT42: Provides for the installation of 3/4" custom door
and grille panels.
• ZKHT1: Provides for the installation of a custom handle
using 3/4" door and grille panels. (This kit must be used
in conjunction with ZKT42.)
Additional Specifications
• A 115 volt 60 Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or
circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall. Electrical must be located on rear wall.
• Water line can enter opening through the floor or back
wall. The water line should be 1/4" O.D. copper tubing
between the cold water line and water connection
location, long enough to extend to the front of the
refrigerator. Installation of an easily accessible shut off
valve in the water line is recommended.
Clearances
If the refrigerator is to be installed in a corner:
• A 2" min. clearance between the case trim and
adjacent wall on both sides of the refrigerator will
assure a 90
°
door opening and access to all drawers.
An 8" clearance is required on both sides for removal
of pans.
6
APPEARANCE
OPTIONS
Monogram
Dimensions &
Specifications