FG177 PROVER RevB17 04-04-17 

12 

 

 
8.0  OPERATING CONDITIONS

 

 
 
 
 

1

 

The prover should always be positioned on a flat, level floor.  This is essential 
for safety reasons and also to ensure that the steaming reservoir is safely and 
easily replenished with water. 

 
 
 

2

 

The prover should be sited so that its door(s) can be opened to its full extent.  

 

This will enable the prover to be loaded and unloaded easily. 

 
 
 

 
3

     For  best  results  ensure  cleaning  and  operating  instructions  are  followed 

meticulously. 

 

 
 

4

 

 It is the customer’s responsibility to install and maintain an adequate water 
supply. 

 

Customers operating the prover in hard water areas must ensure that an 
efficient water treatment device protects the water supply to the prover

.  

 --MONO

 is happy to advise on a suitable unit

--

 

 

Summary of Contents for FG177

Page 1: ... PROVER RevB17 04 04 17 1 OPERATING AND MAINTENANCE MANUAL FG177 PROVER CABINET www monoequip com Enter Serial No here ____________________________ In the event of an enquiry please quote this serial number ...

Page 2: ...FG177 PROVER RevB17 04 04 17 2 ...

Page 3: ...ULD BE TAKEN WHEN THE MACHINE COMES TO THE END OF ITS WORKING LIFE ALL PARTS SHOULD BE DISPOSED OF IN THE APPROPRIATE PLACE EITHER BY RECYCLING OR OTHER MEANS OF DISPOSAL THAT COMPLIES WITH LOCAL REGULATIONS IN UK ENVIRONMENTAL PROTECTION ACT 1990 APPLIES As it is our policy to improve our machines continuously we reserve the right to change specifications without prior notice ...

Page 4: ...ion 3 0 Specifications Section 4 0 Safety Section 5 0 Installation Section 6 0 Isolation Section 7 0 Cleaning Instructions Daily Weekly Section 8 0 Operating Conditions Section 9 0 Operating Instructions Section 10 0 Trouble shooting Section 11 0 Spares Information Section 12 0 Electrical Information ...

Page 5: ...e stand of a bake off oven making it space saving or on its own as a free standing piece of equipment under a worktop etc It is thermostatically controlled and with a manual water fill button creates the atmosphere you require for your dough before baking Available in various tray sizes with either solid or glass doors GLASS DOORS SOLID DOORS ...

Page 6: ...FG177 PROVER RevB17 04 04 17 6 2 0 OVERALL DIMENSIONS HEIGHT 900mm DEPTH 1065mm WIDTH 780mm HEIGHT 930mm DEPTH 850mm WIDTH 1000mm SINGLE DOOR DOUBLE DOOR ...

Page 7: ...l Power Single element 230v 1 ph 50hz 1kw 4 5amps Double element 230v 1 ph 50hz 2kw 8 8amps Weight Single element 80kg Double element 110kg Noise Level Less than 85 dB As it is our policy to improve our machines continuously we reserve the right to change specifications without prior notice ...

Page 8: ...ll repairs and maintenance of electrical units must only be carried out by authorised electricians 8 All connections to the prover must be made in accordance with the statutory requirements of the country of installation 9 It is the customer s responsibility to install and maintain an adequate water supply Customers operating the prover in hard water areas must ensure that an efficient water treat...

Page 9: ...ted so that its door s can be opened to its full extent This will enable the prover to be loaded and unloaded easily 3 In the interests of hygiene we strongly recommend that you clean the inside and outside of your prover with hot water and approved mild detergent before using it for the first time Although the utmost care is taken during assembly and pre delivery inspection there is always a poss...

Page 10: ...FG177 PROVER RevB17 04 04 17 10 6 0 ISOLATION To stop the prover in an emergency switch off at the wall isolator ...

Page 11: ...dles and spot clean prover with a sterilising solution Do not allow water to enter control panel switches ISOLATE MACHINE FROM MAINS SUPPLY AND ALLOW TO COOL BEFORE COMMENCING CLEANING Weekly cleaning instructions 1 Follow daily cleaning instructions 2 Remove the water tray in the bottom and clean the floor of the prover Be careful not to bend the exposed element 3 Replace the water tray carefully...

Page 12: ...d so that its door s can be opened to its full extent This will enable the prover to be loaded and unloaded easily 3 For best results ensure cleaning and operating instructions are followed meticulously 4 It is the customer s responsibility to install and maintain an adequate water supply Customers operating the prover in hard water areas must ensure that an efficient water treatment device protec...

Page 13: ...FG177 PROVER RevB17 04 04 17 13 9 0 OPERATING INSTRUCTIONS CONTROLS POWER ON OFF WATER SUPPLY CONTROL HEAT INDICATOR LIGHT TEMPERATURE SETTING 1 2 3 4 TIMER CONTROL WHEN FITTED ...

Page 14: ...n and close the door s 4 Turn the temperature setting button 4 to the required temperature Usually about 40 degrees The heat indicator light 3 will come on 5 When the light goes out it means the prover is ready for use Usually about 30minutes depending on the ambient temperature etc 6 Check the water level every hour when the prover is in use and top up using water supply button 2 when required NO...

Page 15: ...rature usually about 40 degrees The heat indicator light 3 will come on 5 When the light goes out it means the prover is ready for use Usually about 30minutes depending on the ambient temperature etc 6 Check the water level every hour when the prover is in use and top up using water supply button 2 when required 7 If auto switching mode is required then the operator must insure there is water in t...

Page 16: ...FG177 PROVER RevB17 04 04 17 16 TIMER SETTING ...

Page 17: ...firmly closed during operation Do not allow product to stand in the bakery before loading the prover Control panel knob not operating 2 Humidity too high or too low Humidity will vary if door is opened frequently or the prover has not warmed up enough at the start of operation Humidity will also vary according to the amount of product in the prover Please take account of these factors ...

Page 18: ...stat will operate The cause should be investigated and corrected and then the overheat stat should be reset TURN OFF THE POWER TO THE PROVER To reset the stat the rear panel must be removed 4 screws Press the reset button and replace the back panel before turning the power back on RESET BUTTON REAR VIEW WITH BACK SHEET REMOVED RESET BUTTON POSITION ...

Page 19: ...ICATOR B842 34 010 7 DAY TIMER IF FITTED B842 30 004 THERMAL SWITCH 70C If a fault arises please do not hesitate to contact the Customer Service Department quoting the machine serial number on the silver information plate of the machine and on the front cover of this manual SPARES and OVERSEAS SUPPORT MONO Queensway Swansea West Industrial Estate Swansea SA5 4EB UK email spares monoequip com Web s...

Page 20: ...FG177 PROVER RevB17 04 04 17 20 12 0 ELECTRICAL INFORMATION ...

Page 21: ...FG177 PROVER RevB17 04 04 17 21 ...

Page 22: ...sway Swansea West Industrial Park Swansea SA5 4EB UK Tel 01792 561234 Fax 01792 561016 Email mono monoequip com www monoequip com As it is our policy to improve our machines continuously we reserve the right to change specifications without prior notice ...

Reviews: