5. Programming of positions
1. When commissioning the mySwing TV wall mount, first define your preferred positions. Various selected angles can be
stored on the "IN", "OUT", "P1" and "P2" buttons on the remote control and automatically recalled by pressing the
button. Please note that the complete recall of an automatic movement process consists of several individual steps,
between which there may be a waiting time of a few seconds.
2. Fully extend the wall mount by pressing the "OUT" button (the preset default value is 90°). If you want to assign a new
angle to the "OUT" button, you can set this angle using the arrow keys. To do this, move the mount freely to the left or
right by holding down the respective arrow key until the desired position is reached. Releasing the arrow key stops the
movement. Now press "M" + "OUT" simultaneously to store the currently selected position on the "OUT" button. A
double signal tone is heard for confirmation. The default value is now overwritten with the currently selected position.
3. Additional preferred positions can be saved on the "P1" and "P2" buttons. To do this, set the desired position using the
arrow keys as described above and simultaneously press "M" + "P1" or "M" + "P2" to save the currently selected position
on the "P1" or "P2" button. A double signal tone is heard for confirmation. The default value is now overwritten with the
currently selected position.
4. By pressing the "IN" button, the mount moves back to its initial position (the preset default value is 0°). If you want to
assign a new angle to the "IN" button, you can also set this angle using the arrow keys. Then press "M" + "IN"
simultaneously to save the currently selected position on the "IN" button. A double signal tone is heard for confirmation.
The default value is now overwritten with the currently selected position.
Attention: The mySwing mount does not have a global reset function. If you want to change a saved position, overwrite it