SiloTrack
TM
Cloud Gateway
Power Requirements
AC Verson: 115-230VAC ± 15%, 50/60 Hz
DC Version: 24VDC ± 15%
Power Consumption
AC Verson: 70W
(1.5A max @ 115VAC)
DC Version: 18W max
AUX 24VDC Output: 1.7A max (AC Version Only)
Ambient Operating Temp: -30° F to 149° F (-34° C to 65° C)
Sensor Communication: RS-485 half-duplex,
non-isolated,
Modbus RTU protocol
9600/8/N/1
Max. 3,300ft (1000m) @ 9600 Baud
Sensor Channels: One (1) 32-channel network
(32 channels total)
Cellular Wireless
LTE CAT 4:
Interface:
700(B12,13)/850(B5)/AWS(B4)/1900(B2)
[LTE - North America (M5)] 3G HSPA+: 850/1900 MHz
Transfer rate (max):
150 Mbps down, 50 Mbps up
FCC ID: R17LE910NA V
Emissions / Immunity:
CE, FCC Part 15 Class B, AS/NZS
CISPR 22, EN55024, EN55022 Class B
Indicators
Router: 7 LED’s
(Power, Service, WWAN, 3x Signal
Strength, System - Not Used)
RS-485 Booster: 3 LED’s
(Power, Transmit, Receive)
Firewall Ports: 3197, 3199
(Ethernet Only)
Enclosure Material: PBT / PC
Enclosure (HxWxD): 12” x 8” x 6.4"
(305mm x 203mm x 163mm)
Environmental Protect: ENCLOSURE TYPE 4X, IP65
Approvals
Power Supply: UL Listed (US and Canada)
Router: UL Listed (US and Canada)
Monitor Technologies LLC warrants each
Silo
Track
TM
CLOUD
Gateway it manufactures to be free from defects in material and
workmanship under normal use and service for two (2) years
from the date of purchase. The purchaser must notify Monitor of
any defects within the warranty period, return the product intact,
and prepay transportation charges. The obligation of Monitor
Technologies LLC under this warranty is limited to repair or
replacement at its factory. This warranty does not apply to any
product which is repaired or altered outside of Monitor
Technologies
’
factory, or which has been subject to misuse, neg-
ligence, accident, incorrect wiring by others, or improper installa-
tion. Monitor Technologies LLC reserves the right to change the
design and/or specifications without prior notice.
WARRANT Y
SPECIFICATIONS
General Safety
CAUTION: It is essential that all instructions in this manual be
followed to ensure proper operation of the equipment and safety
of operating personnel. The use of this symbol is used through-
out this manual to highlight important safety issues. Please pay
particular attention to these items.
Electrical Shock Caution
The
Silo
Track
TM
CLOUD
Gateway is powered with HIGH VOLTAGE.
No operator serviceable parts are inside. All servicing is to be
performed by qualified personnel. Each
Silo
Track
TM
CLOUD
Gateway is provided with a “protective conductor terminal”
which shall be terminated to earth ground potential.
(See “Electrical Installation” section)
SAFET Y
9