background image

CLG140

CLG160

Frequency Response  (-6dB)

100Hz – 30KHz

80Hz – 30KHz

Sensitivity (1W@1m)   

88dB

89dB

Line Level Voltage   

70/100

70/100

Maximum S.P.L

104 dBA 

107 dBA 

Power Handling 

40 watts (crossover set to minimum 

100Hz@12dB/Octave)

60 watts (crossover set to minimum 

80Hz@12dB/Octave)

Amplifier Requirements 

(RMS)

10-40 watts per speaker

10-60 watts per speaker

Driver Complement

1 x 4” MMPII cone bass-mid driver

1 x 25mm C-CAM Gold Dome tweeter – 

Coaxially oriented

1 x 6” MMPII cone bass-mid driver

1 x 25mm C-CAM Gold Dome tweeter – 

Coaxially oriented

Crossover Recommendation 

(high pass)

100Hz at a minimum of 12dB/Octave 

(24dB/Octave optimum)

80Hz at a minimum of 12dB/Octave (24dB/

Octave optimum)

External Dimensions, 

excluding spike/ mount 

(Diameter x D)

130 x 175mm (5

1/8

 x 6

7/8

 inches)

190 x 220mm (7

1/2

 x 8

11/16

 inches)

Bracket Pivot Angle

32° in all directions

32° in all directions

Connection

Encapsulated cable connection

Encapsulated cable connection

Environmental Protection 

Rating

IP55

IP55

Finishes Available

Brown

Brown

Weight

2.08kgs (4lb 10oz)

2.76 kg (6lb 2oz)

Dispersion

 60°

 60°

Specifications

Climate Garden Series

8

Summary of Contents for CLG-W12

Page 1: ...d e G u i d e d i n s t a l l a t i o n M a n u a l e d i i n s t a l l a z i o n e I n s t a l l a t i o n s a n l e i t u n g G u a d e i n s t a l a c i n G u i a d e i n s t a l a o I n s t a l l...

Page 2: ...cations 8 Guarantee 9 English 1 Fran ais 10 Italiano 20 Deutsch 30 Espa ol 40 Portugu s 50 Nederlands 60 70 80 90 100 Introduction Bring high fidelity sound to the great outdoors with Monitor Audio s...

Page 3: ...t the speaker from D C offset or D C amp faults The speakers should be connected in parallel from a single cable run per channel We also recommend using the Crown CDi 2000 amplifier and our bespoke DS...

Page 4: ...nd can be levelled made square NOTE Ensure the system is tested and working correctly before filling in around the subwoofer and cable tenches NOTE The bass from the CLG W12 will not be as full or pro...

Page 5: ...ing this so that no pressure is placed on the pivoting section ENGLISH CLG140 CLG160 With Spike NOTE Ensure the system is tested and working correctly before filling in around the subwoofer and cable...

Page 6: ...xing arm and top half of the mount assembly attach loosely with four screws ii CLG140 CLG160 Wall Mount CLG140 CLG160 Tree Mount HINT To assist in threading the speaker cable through the mount we woul...

Page 7: ...2000 amplifier For optimum performance from the system download the Monitor Audio Crown CDi 2000 preset DSP settings from our website www monitoraudio com These preset DSP settings have been designed...

Page 8: ...ow for the addition of any subwoofers Monitor Audio Preset DSP List CLG DUAL Channel 1 has a low pass filter for the subwoofer and Channel 2 has a high pass filter for the satellite speakers CLG SATS...

Page 9: ...Crown CDi 2000 via USB cable to your computer and switch on the power button the ready LED and power button will become illuminated 7 Once discovered a pop up will appear in Audio Architect check Add...

Page 10: ...1 x 6 MMPII cone bass mid driver 1 x 25mm C CAM Gold Dome tweeter Coaxially oriented Crossover Recommendation high pass 100Hz at a minimum of 12dB Octave 24dB Octave optimum 80Hz at a minimum of 12dB...

Page 11: ...the need arise please take a few minutes to register your product s online at www monitoraudio com CLG W12 Frequency Response 6dB 30Hz 100Hz Sensitivity 1W 1M 87dB Impedance nominal 4 Ohms or 70 100 V...

Reviews: