background image

 

 

 

 

CC-8521B 

CRYPTO 

-LOCK 

Low Battery 

Warning Output 

Stand-by 
Batteries 

External 

Annunciator 

Output 

Magnetic Lock

(fail-safe) 

Release 

Button 

Keypad with 

Status LED 

Electric Lock or Strike 

(fail-secure) 

115/230 Vac, 

50/60Hz 

Figure 1, Typical Installation

 

Door 

Switch 

Summary of Contents for Crypto-Lock CC-8521B

Page 1: ...CRYPTO LOCK Model CC 8521B Access Control System Instruction Manual Ed 11 17 Moniteq Inc...

Page 2: ...2...

Page 3: ...s Introduction 4 Specifications 6 Supplied Equipment 7 Functions of Controls and Indicators 8 KEYPAD 8 PROGRAMMING MODE 8 CONTROL UNIT 8 Installation 9 Setup 10 Programming 12 Operating Procedure 14 L...

Page 4: ...ks The control unit can house two optional 12V 7AH sealed lead acid batteries not included and maintain them at full charge Audible and visual warnings will occur when the charge level is low Security...

Page 5: ...attery Warning Output Stand by Batteries External Annunciator Output Magnetic Lock fail safe Release Button Keypad with Status LED Electric Lock or Strike fail secure 115 230 Vac 50 60Hz Figure 1 Typi...

Page 6: ...SPDT Form C Battery Backup 12VDC or 24VDC automatic transfer and charging batteries optional Enclosure Description 19 gauge steel powder coated paint gray color knockouts for conduit and cam lock inc...

Page 7: ...tted Sheet Metal 6 Hold Control Unit Door Closed 2 Battery Cables 18 AWG Black Red Connect Batteries to Board 2 Fuse 5 x 20MM 4A Slo Blo Spares 4 Hex Nut 8 Keypad Mounting 2 Acorn Nut 8 Keypad Mountin...

Page 8: ...id programming entry CONTROL UNIT Penalty LED illuminates when invalid PIN penalty feature is activated AC Power LED illuminates when the system is AC powered Battery Power LED illuminates when the sy...

Page 9: ...or does not need to be locked the two supplied 6 x screws can be used in the holes on the door edge to hold it closed Note all cables passing through the knockout holes in the enclosure must be protec...

Page 10: ...switch to LIMIT when used with Brute electric lock or a similar heavy duty solenoid operated lock Set this switch to DIRECT when used with standard electric strikes or magnetic locks 3 Connect the pow...

Page 11: ...11 Figure 2 Wiring Diagram...

Page 12: ...or 5 minutes Initial Settings During a new installation or if existing settings are unknown it is recommended that the default values for all PIN and door monitoring settings be reset by entering 00 o...

Page 13: ...hen this function is enabled the door re locks immediately after it closes regardless of the open duration setting Door Propped Alarm The door propped alarm function sounds an alarm when the door rema...

Page 14: ...he unit will return to normal operation and entering the valid PIN code on the keypad will release the door If the external release button has been installed it can be used by an attendant to release...

Page 15: ...15...

Page 16: ...in cases of abuse misuse mishandling modification or repair by unauthorized persons This warranty is given in lieu of all other warranties expressed or implied Moniteq Inc is not liable for incidenta...