6.

OPERATING PROCEDURE

To operate the CC-8521A

N

, enter the 

valid 3, 4, or 5 digit PIN code on the 
keypad.  When the valid PIN code is 
entered, the green LED on the Keypad 
will illuminate and the door will release. 

The CC-8521A

N

 Keypad has a built-in 

annunciator button. Pressing this button 
causes an annunciator to sound in the 
Control Unit.  If an external annunciator is 
connected as shown in Figure 3 it will also 
sound when this button is pressed. 

If one or more incorrect PIN code digits 
are entered the system will enter a penalty 
mode and will not recognize any digits for 
the time period set by the PENALTY 
control on the Logic Board in the Control 
Unit.  After the penalty time has elapsed 
the unit will return to normal operation and 
entering the valid PIN code on the Keypad 
will release the door. 

If the external Release Button has been 
installed it can be used by an attendant to 
release the lock from the secure side of the 
door.  

Summary of Contents for CRYPTO-LOCK CC-8521AN

Page 1: ...CRYPTO LOCK Model CC 8521AN Single Door Access Control System 2 20 MONITEQ Inc...

Page 2: ...2...

Page 3: ...CATIONS 6 3 SUPPLIED EQUIPMENT 7 4 FUNCTIONS OF CONTROLS AND INDICATORS 8 A KEYPAD 8 B LOGIC BOARD 8 C POWER SUPPLY BOARD 8 5 INSTALLATION AND SETUP 9 A INSTALLATION 9 B SETUP 9 6 OPERATING PROCEDURE...

Page 4: ...lock remains released after entry of the valid PIN is adjustable from 3 to 60 seconds An invalid PIN penalty feature provides for ignoring all keypad entries for from 3 to 60 seconds after an invalid...

Page 5: ...z Magnetic lock fail safe Electric lock or strike fail secure External Annunciator Output Low Battery Warning Output KEYPAD WITH STATUS LED AND VISITOR BUTTON Figure 2 Typical Installation of the Cryp...

Page 6: ...d cam lock included holes to accommodate padlock not included Dimensions 12H x 9W x 4 5D in Option available CC BATT 12Vdc 7AH rechargeable battery two required enclousure does not accomodate Narrativ...

Page 7: ...ach to aid identification and use QTY ITEM PURPOSE 1 Control Unit w shock isolation Main processor and power supply 1 Keypad with 20 water blocking cable Accepts PIN code entries 1 Manual Crypto Lock...

Page 8: ...ts either 3 4 or 5 digits for the length of the PIN code POWER Indicator LED Indicates that the Logic Board is powered C POWER SUPPLY BOARD OUTPUT VOLTAGE SOURCE INT 24V EXT or INT 12V Selects the vol...

Page 9: ...so that the padlock hole on the door also passes over the shackle If the door does not need to be locked two screws can be used in the door edge holes to hold it closed 5 Connect the Keypad to the Con...

Page 10: ...er cord to an appropriate source of AC power and verify that the POWER indicators illuminate 8 Enter the valid PIN code on the keypad and verify that the lock releases and that the green LED on the Ke...

Page 11: ...Driver T3 1 2 3 115 Vac BRN WHT GRN RED N C 230 Vac BRN GRN WHT RED PCB G9844 94V 01 PCB Rev C Low Battery Warnings The LOW BATT indicator will light and a beep will sound every 15 seconds when the b...

Page 12: ...connected as shown in Figure 3 it will also sound when this button is pressed If one or more incorrect PIN code digits are entered the system will enter a penalty mode and will not recognize any digit...

Page 13: ...and causing the 1 decoded output U4 pin 1 to go high If the second digit from the keypad is also valid the process repeats again advancing the counter When the last correct digit is entered a high sig...

Page 14: ...rough T2 pin 16 Terminals T3 and T4 are provided to allow wiring the power transformer primary winding for either 115VAC or 230VAC Refer to Figure 3 for correct wiring of T3 and T4 of K1 Capacitor C3...

Page 15: ...15...

Page 16: ...of abuse misuse mishandling modification or repair by unauthorized persons This warranty is given in lieu of all other warranties expressed or implied MONITEQ INC is not liable for incidental or conse...

Reviews: