3) Set the # OF DIGITS switch to the
desired
number of PIN digits (3, 4 or 5)
.
4) Set the valid PIN code using the DIGIT
DIP switches. DIP switches for unused
digits can all be set to OFF.
5) Set the DURATION control to the
approximate desired open time. (Min.=3
sec., Max.=60 sec.)
6) Set the PENALTY control to the
approximate desired PENALTY time
(Min.=3 sec., Max.=60 sec.)
7) Connect the power cord to an
appropriate
source of AC power and verify
that the POWER indicators illuminate.
8) Enter the valid PIN code on the keypad
and verify that the lock releases and that
the green LED on the Keypad illuminates.
2) Set the OUTPUT MODE switch to
LIMIT
HOLDING CURRENT for use
with the Sargent Greenleaf Brute lock or
other devices that can be damaged by
holding currents in excess of 300 mA.
For other locks and magnetic releases
select the DIRECT position.
B. SETUP
1) Set the OUTPUT source switch in
accordance with the voltage rating of the
lock being used (12 or 24 Vdc).