CLEARANCES
CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE: The combustible area around the fireplace must
not protrude more than
1
/
2
" from the facing. If it does, it is
considered a mantel and must meet the mantel requirements
listed in this manual.
Figure 6 - Clearances from the Mantel,
Ceiling, and Side Wall
WARNING
Follow these instructions carefully to ensure safe installation. Failure to follow
in struc tions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be
installed on a metal, wood or noncombustible material panel ex tend ing full width and
depth of the appliance.
Figure 7 - Mantel Clearances