Monessen • Glow Getter Owner’s /Installation Manual • 4606-900 Rev. A • 8/17
6
E. Installation Information
Use manufacturer's installation and clearance require-
ments as defined in their manual.
The GG18, 24, 30 series unvented room heaters are
approved for installation into the following unvented fire
-
boxes: MCUF, LCUF, GCUF, GRUF, BUF and Exacta.
The Glow Getter Series unvented room heaters may also
be installed into a Ventless Firebox Enclosure for Gas Fired
Decorative Type Unvented Room Heaters per ANSI Z21.91
(typically referred to as a "universal firebox"), as long as
firebox hearth dimensions meet the minimum hearth dimen
-
sions shown below.
A
C
D
B
Figure 2.1 - Dimensions for Engine, Logs & Firebox
Model
A
B
C
D
GG18 with LOGS
25”
13"
20”
12"
GG24 withLOGS
29”
13"
24”
13”
GG30 with LOGS
32”
13”
24”
13”
This appliance is for installation only in a solid-fuel
burning masonry or UL127 factory-built fireplace
or in listed ventless firebox enclosure. It has been
design certified for these installations.
Exception:
DO NOT install this appliance in a factory-
built fireplace that includes instructions stating
it has not been tested or should not be used with
unvented gas logs.
WARNING
Model
A
B
C
D
GG18 with LOGS
27”
14”
20”
20”
GG24 with LOGS
31”
14"
24”
21”
GG30 with LOGS
34”
14”
24”
21”
Firebox Dimension Requirements
Dimensions for Engine & Logs
D. Check Parts
Verify contents to ensure you have received all parts. You
should have the following:
Models
•
Unvented gas log burner assembly
•
One (1) bag of crushed volcanic rock
•
Installation/operating instructions
•
Two (2) anchoring brackets
•
Two (2) anchoring screws
•
Two (2) sheet metal scews
•
Refractory logs (packaged and sold separately)
•
Two (2) bags of rock wool
•
On/off log switch assembly
The following options may be used with the millivolt con
-
trolled heater. These options are
not
packaged with the
log set.
•
Hand-held remote with receiver (MV)
• Wall switch with 15' wire
•
HILOKT (an accessory kit for flame adjustment from
a hand held remote)
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance.
Do not
attempt to install any part of the appliance unless you
have all parts in good condition.