CDVSC7 & CDV7 Series Gas Fireplace
69D3011
9
pRe-InSTallaTIon InFoRMaTIon
BeFoRe you STaRT
Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that
all listed parts have been received. You should have the
following:
•
Fireplace (Firebox and Burner System)
•
Log Set
•
Volcanic Rock
•
Rock Wool
ITeMS RequIReD FoR InSTallaTIon
Tools:
Building Supplies:
•
Phillips Screwdriver
•
Framing Materials
•
Hammer
•
Wall Finishing Materials
•
Saw and/or saber saw
•
Level
•
Electric Drill and Bits
•
Tee Joint
•
Pliers
•
Measuring Tape
•
Square
•
Pipe Wrench
•
Caulking Material (Noncombustible)
•
Fireplace Surround Material (Noncombustible)
•
Piping Complying with Local Codes
•
Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)
FIReBox FRaMInG FoR CDVR
Firebox framing can be built before or after the appliance
is set in place. Construct firebox framing following
Figure 2
for your specific installation requirements.
Refer to Figure
2
for firebox dimensions. The framing headers may rest
on the top of the firebox standoffs.
Do not bring headers
below top of standoffs. noTe: CDVR33SC7 does not
have standoffs.
The firebox may be installed directly on a combustible floor
or raised on a platform of an appropriate height. When
the firebox is installed directly on carpeting, tile, or other
combustible material, other than wood flooring, the firebox
shall be installed on a metal or wood panel extending the
full width and depth of the enclosure.
w
a
R
n
In
G
Do not fill spaces around firebox with
insulation or other materials. This could
cause a fire.
FIReBox FRaMInG FoR CDVT
Firebox framing can be built before or after the appliance
is set in place. Construct firebox framing following
Figure 3
for your specific installation requirements.
Refer to Figure
3
for firebox dimensions. The framing headers may rest
on the top of the firebox standoffs.
Do not bring headers
below top of standoffs.
The firebox may be installed directly on a combustible floor
or raised on a platform of an appropriate height. When
the firebox is installed directly on carpeting, tile, or other
combustible material, other than wood flooring, the firebox
shall be installed on a metal or wood panel extending the
full width and depth of the enclosure.
no
T
e
ColD ClIMaTe InSulaTIon
If you live in a cold climate, seal all cracks around your appliance, and
wherever cold air could enter the room, with noncombustible material.
It is especially important to insulate the outside chase cavity between
the studs and under the floor on which the appliance rests, if the floor
is above ground level.