background image

9.

This product contains Nickel Metal Hydride batteries which
must be disposed of in accordance with Federal, State, & Local
Regulations.  Do not incinerate.  Batteries should be shipped to
a reclamation facility for recovery of the metal and plastic
components as the proper method of waste management.
Contact distributor for appropriate product return procedures.

10. This instrument is not user serviceable.  For technical

assistance, contact the sales organization from which you
purchased the product or Monarch Instrument directly.

In order to comply with EU Directive 2002/96/EC on Waste
Electrical and Electronic Equipment (WEEE):  

This product

may contain material which could be hazardous to human health
and the environment.  DO NOT DISPOSE of this product as un-
sorted municipal waste.  This product needs to be RECYCLED in
accordance with local regulations, contact your local authorities

for more information.  This product may be returnable to your distributor for
recycling - contact the distributor for details.

Monarch Instrument’s Limited Warranty applies.  See
www.monarchinstrument.com  for details.
Warranty Registration and Extended Warranty coverage available
online at www.monarchinstrument.com.

10.0 OPTIONS AND ACCESSORIES

PSC-pbxU

Universal Power Supply/Charger, 115/230 Vac with
USA, U.K., AUS and Euro Adapter Plugs (one supplied
with unit)

C-4027

Set of mating 1/8 inch (3.5mm) stereo phone plugs (to
provide TTL signal and sensor power)

CA-4044-6

6 foot (1.8M) input / output cable, 1/8 inch (3.5mm)
male phone plug to male BNC connector

CA-4045-6

6 foot (1.8M) input / output cable, 1/8 inch (3.5mm)
male phone plug to 1/8 inch (3.5mm) male phone plug
for daisy chaining strobes together

CC-7

Latching carrying case for Strobe with provision for
accessories

L-1903

Digital Stroboscope replacement lamp

SPC-1

Splash proof Protective Cover for battery model
Stroboscopes ONLY

ROS-P

Remote Optical Sensor with 8 foot (2.5 m) cable for
triggering strobe

T-5

Reflective tape. 5 foot (1.5 m) roll, 0.5 inch wide

MT-190P

Magnetic Sensor/Amplifier with 8 foot (2.5 m) cable
for triggering strobe

IRS-P

Infrared Sensor for use without reflective target at 0.5
inch (12 mm) gap with 8 foot (2.5 m) cable for triggering
strobe

22

Summary of Contents for Phaser Strobe PBX

Page 1: ...Strobe pbx Portable Phase Shifting Stroboscope MONARCH INSTRUMENT Instruction Manual Printed in the U S A Copyright 2008 Monarch Instrument all rights reserved 1071 4210 112R 1009 www 64817 com www 64...

Page 2: ...serious damage to the equipment or severe personal injury or death may occur as a result 8 This instrument may not be safe for use in certain hazardous environments and serious personal injury or deat...

Page 3: ...or details Monarch Instrument s Limited Warranty applies See www monarchinstrument com for details Warranty Registration and Extended Warranty coverage available online at www monarchinstrument com 10...

Page 4: ...power down is remembered and restored on next power up 9 user settable flash rates Output Pulse 40 sec positive negative pulse menu selectable 3 3 Vdc typical Input Power Internal Rechargeable Batteri...

Page 5: ...NS Internal Mode Flash Range 30 50 000 FPM Flashes Per Minute Flash Rate Accuracy 0 004 of setting or last digit Flash Rate Resolution 0 01 to 1 FPM menu selectable 0 1 FPM max resolution above 9 999...

Page 6: ...hase Time and Auto VRPM 19 8 3 External Power Supply Charger The external power supply charger PSC pbxU can also be used to run the stroboscope continuously from the AC mains 115 230 Vac To power the...

Page 7: ...ccept 1 8 3 5mm phone plugs input stereo output mono The input and output are TTL compatible See Figures 2 and 3 for connector connection detail 18 by no flash and the display shows LO BAT At this tim...

Page 8: ...se batteries contain fewer toxic metals than NiCd Nickel Cadmium and are currently classified environmentally friendly They also have 30 more capacity than NiCd batteries of the same size Like NiCds N...

Page 9: ...then the MENU button 2 SETUP and the menu option will be displayed 3 Turn the tuning knob to cycle through the main menu options 4 Once the desired menu option is displayed press the MENU button to s...

Page 10: ...ource location 4 1 Internal Mode Standard Strobe Operation In the Internal Mode the stroboscope generates it s own signals and functions like a tunable stroboscope The strobe is in the Internal Mode w...

Page 11: ...up to the maximum flash rate This is very helpful on fan blades Using this feature one can superimpose the blades on top of each other and check for blade tracking bent blades lead and lag tests etc 1...

Page 12: ...played 13 Example Object Rotating at 5000 RPM If the speed is outside the full scale range of the stroboscope 50 000 FPM it can be measured using the method of harmonics and multipoint calculation Sta...

Page 13: ...ed to be considered First the object being measured should be visible for all 360 of rotation e g The end of a shaft Second the object should have some unique part on it like a bolt key way or imperfe...

Page 14: ...y Modes Phase Delay Time Delay and Auto Virtual RPM In the External Phase Delay Mode the flash is triggered 0 1 to 359 9 degrees after each external signal pulse The knob sets the amount of delay in d...

Reviews: