External Input Mode

The strobe is in the External Input Mode whenever there is a plug in
the input jack. When the strobe is in the External Input Mode, 

EXT

will be displayed.

In the External Input Mode the user can’t make any flash rate adjustments.
The flash rate is a function of the input signal. This mode is used to
synchronize the flash to an external event (for example, from an optical
sensor) to stop or freeze motion. The flash will be triggered on the rising or
falling edge (menu selectable) of the external input pulse.

4.4

Tachometer Mode - External Input Required

When an external input is supplied to the unit and the strobe is put in
the Tachometer Mode, the unit will read the signal from the external
input (sensor) and display the reading on the LCD display without
flashing the lamp.  

The strobe will not flash in the Tachometer

Mode.

To enter the Tachometer Mode:

1.

Press the 

ALT FUNCTION

 button and then the 

TACH

 button.

2.

The 

TACH

 icon will be displayed.

NOTE:

If the external input signal exceeds the maximum flash rate,
the strobe will go into the Tachometer Mode automatically.

To exit the Tachometer Mode:

1.

Press the 

ALT FUNCTION

 button and then the 

TACH

 button.

2.

The 

TACH

 icon will go away.

11

4.5

External Delay Modes (Phase Shifting)

There are three 

External Delay Modes

:  

Phase Delay

Time Delay

, and

Auto (Virtual RPM)

.  In the 

External Phase Delay Mode

 the flash is

triggered 0.1 to 359.9 degrees after each external signal pulse.  The knob
sets the amount of delay in degrees.  In the 

External Time Delay Mode

the flash is triggered 0.01 to 1000 milliseconds after each external signal
pulse.  The knob sets the amount of delay in milliseconds.  In the 

Auto

(Virtual RPM) Mode 

the flash is triggered by increasing amounts after

the external trigger pulse so that the image will appear to rotate at a given
(virtual) RPM or RPS.  The knob sets this virtual RPM or RPS.

To enter one of the External Delay Modes:

1.

Ensure there is an external input plugged in (so the unit is in
External Input Mode).

2.

Press the 

Phase Delay 

button to cycle to the desired mode.

3.

Use knob to adjust delay/angle (phase, time or virtual RPM).

To exit the External Delay Mode:

1.

Press the 

PHASE DELAY

 button to cycle back to External only.

2.

The word 

PHASE

 or the 

TIME

 or 

AUTO

 icon will go away.

4.6

Power Up Features

When the strobe is powered up it will remember the last settings.

Press and hold the 

x2/MENU

 button, then turn on the strobe by

depressing the trigger switch.  This will turn on all the display segments
for two seconds or until you release the button. It will then show the
software revision, “REV x.x” and then go through a display diagnostic.

Press and hold the 

÷2

 button, then turn on the strobe by depressing

the trigger switch.  This will restore the factory programmed presets.

Summary of Contents for Phaser Strobe PBX

Page 1: ...Strobe pbx Portable Phase Shifting Stroboscope MONARCH INSTRUMENT Instruction Manual Printed in the U S A Copyright 2008 Monarch Instrument all rights reserved 1071 4210 112R 1009 www 64817 com www 64...

Page 2: ...serious damage to the equipment or severe personal injury or death may occur as a result 8 This instrument may not be safe for use in certain hazardous environments and serious personal injury or deat...

Page 3: ...or details Monarch Instrument s Limited Warranty applies See www monarchinstrument com for details Warranty Registration and Extended Warranty coverage available online at www monarchinstrument com 10...

Page 4: ...power down is remembered and restored on next power up 9 user settable flash rates Output Pulse 40 sec positive negative pulse menu selectable 3 3 Vdc typical Input Power Internal Rechargeable Batteri...

Page 5: ...NS Internal Mode Flash Range 30 50 000 FPM Flashes Per Minute Flash Rate Accuracy 0 004 of setting or last digit Flash Rate Resolution 0 01 to 1 FPM menu selectable 0 1 FPM max resolution above 9 999...

Page 6: ...hase Time and Auto VRPM 19 8 3 External Power Supply Charger The external power supply charger PSC pbxU can also be used to run the stroboscope continuously from the AC mains 115 230 Vac To power the...

Page 7: ...ccept 1 8 3 5mm phone plugs input stereo output mono The input and output are TTL compatible See Figures 2 and 3 for connector connection detail 18 by no flash and the display shows LO BAT At this tim...

Page 8: ...se batteries contain fewer toxic metals than NiCd Nickel Cadmium and are currently classified environmentally friendly They also have 30 more capacity than NiCd batteries of the same size Like NiCds N...

Page 9: ...then the MENU button 2 SETUP and the menu option will be displayed 3 Turn the tuning knob to cycle through the main menu options 4 Once the desired menu option is displayed press the MENU button to s...

Page 10: ...ource location 4 1 Internal Mode Standard Strobe Operation In the Internal Mode the stroboscope generates it s own signals and functions like a tunable stroboscope The strobe is in the Internal Mode w...

Page 11: ...up to the maximum flash rate This is very helpful on fan blades Using this feature one can superimpose the blades on top of each other and check for blade tracking bent blades lead and lag tests etc 1...

Page 12: ...played 13 Example Object Rotating at 5000 RPM If the speed is outside the full scale range of the stroboscope 50 000 FPM it can be measured using the method of harmonics and multipoint calculation Sta...

Page 13: ...ed to be considered First the object being measured should be visible for all 360 of rotation e g The end of a shaft Second the object should have some unique part on it like a bolt key way or imperfe...

Page 14: ...y Modes Phase Delay Time Delay and Auto Virtual RPM In the External Phase Delay Mode the flash is triggered 0 1 to 359 9 degrees after each external signal pulse The knob sets the amount of delay in d...

Reviews: