background image

 

 

clicks  into  place  and  use  the  capve  screw  to  secure  into  place.    Then 

plug  the  wall  power  supply  into  an  outlet  (115Vac  to  230Vac)  using  the 
appropriate interchangeable plug. 

9.  WALL POWER SUPPLIES 

The  wall  power  supplies  provided  with  the  Nova-Pro  100  have 
interchangeable plugs allowing them to be used with AC outlets 
in different countries. 

To  change  the  plugs,  depress  the 

buon (1) and slide the plug up (2).  

Select  the  correct  plug  and  slide  it 

back  into  the  power  supply  unl 

the  plug  seats  firmly.    Make  sure 
the plug cannot slide out. 

CAUTION:    RISK  OF  ELECTRIC 
SHOCK 

• 

Do not insert the plugs into an 
AC  outlet  without  the  power 

supply aached.

 

• 

Avoid  touching  the  plug  blades  when  inserng  or  removing  the  

power supply from the AC outlet. 

• 

Indoor Use Only 

21 

Summary of Contents for Nova-Pro 100

Page 1: ...ro 100 LED Stroboscopes Laser Tachometers 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrument com Instruction...

Page 2: ...serious personal injury or death could occur as a result of improper use Please refer to your facility s safety program for proper precau ons 9 Do not clean this instrument with alcohol or other clea...

Page 3: ...rs Interferes with vision up to 525 ft 160 m away Can be a distraction up to 1 mile 1 6 km away NEVER point any laser towards aircraft or vehicles it is unsafe and illegal Safe use guidance Class 2 la...

Page 4: ...or Halving the Flash Rate 10 4 2 LASER Mode 11 4 3 TACH Tachometer Mode 12 5 MENUS 13 5 1 Menu Overview 13 5 2 MODE Menu 14 5 3 Brightness BRITE Menu 14 5 3 1 Degrees 15 5 3 2 Time 15 5 4 DECPT Decim...

Page 5: ...g the Ba ery Pack 20 8 AC POWER OPTION 20 9 WALL POWER SUPPLIES 21 10 SPECIFICATIONS 22 10 1 Opera ng Environment 22 10 2 Compliance 23 10 2 1 Ba ery Compliance 23 10 2 2 EU Declara on of Conformity 2...

Page 6: ...ota ng objects The Nova Pro 100 is available as ba ery powered or AC mains powered An op onal Laser Module is available which can be used to synchronize the strobe ash to a remote target or used as a...

Page 7: ...bject under inspec on Can also be used in Tachometer Mode 4 Trigger Used to ac vate the unit when power is on 5 Tripod Mount 1 4 20 tripod mount for xed placement opera on 6 Power Source Ba ery Pack R...

Page 8: ...f a large display dedicated keys on the user interface panel and a trigger to ac vate the unit when the power is on The user interface is described in Figure 2 and Table 2 Figure 2 Nova Pro 100 User I...

Page 9: ...de is selected 8 PHASE icon Not used available in Nova Pro 500 model 9 x2 2 and arrows Used to indicate joys ck 11 func on 10 POWER bu on Turns the unit on and o Also used as escape back bu on in menu...

Page 10: ...ppropriate connector Interchangeable plugs allow for operation in most countries see sec on 9 With the power source battery or AC inserted into the Nova Pro turn the unit on by pressing and holding th...

Page 11: ...ng target using re ec ons from a keyway in a sha7 or a piece of re ec ve tape on a fan blade The mode of opera on is selected in the MODE menu See sec on 5 2 4 1 STROBE Mode In this mode the strobe ge...

Page 12: ...isplay will show the x2 and 2 icons Use the le7 and right bu ons on the joys ck to double or halve the ash rate Press the POWER bu on to exit this mode To con rm that the strobe is ashing at the same...

Page 13: ...hen Laser Mode is enabled and be on solid when trigger is pulled and laser is on By pulling the trigger and aiming the laser at a re ec ve target on the rota ng or reciproca ng machine the strobe will...

Page 14: ...hen Laser Mode is enabled and will be on solid when trigger is pulled ac va ng the laser Pull the trigger and aim the laser at a re ec ve target on a rota ng or reciproca ng target The speed will be d...

Page 15: ...e of the display To enter StrobE LASEr or tACH Tachometer Mode press the MENU bu on again then the down arrow and MENU bu on to enter that mode Not all items will be available in the menu it depends i...

Page 16: ...ll be on for the currently selected mode Use the and arrows on the joys ck to select the desired mode Press the MENU bu on to select the desired mode This will change the mode and exit the menu Press...

Page 17: ...MENU bu on followed by the Power bu on to save the degree seEng 5 3 2 Time To set the ash dura on in me instead of degrees press the MENU bu on again skip the DEG menu Use the arrows on the joys ck to...

Page 18: ...menu op on selects the Engineering Units used to display the ash rate or speed The choices are FPM Flashes per Minute Not available in TACH Mode FPS Flashes per Second same as Hz not available in TAC...

Page 19: ...the shaft appeared to be stopped As the target is rotating there is some movement evident during the strobe flash The longer the flash duration the more obvious the rotation is and this increases the...

Page 20: ...ally calculates how wide the pulse width should be at di erent ash rates to keep the blur constant the faster the ash rate the narrower the pulse width The pulse width equals seEng in degrees 360 x 1...

Page 21: ...need to be RECYCLED in accordance with local regula ons The ba eries should be sent to a recycling center or returned to the factory using appropriate shipping methods The Nova Pro Ba ery Pack is spe...

Page 22: ...LED indicates the following Green On No Ba ery or Ba ery Charged Red Charging Flashing Red Error Replace Ba ery Ba ery charge me will be up to 6 hours depending on Ba ery Pack and residual charge Onc...

Page 23: ...gs allowing them to be used with AC outlets in di erent countries To change the plugs depress the bu on 1 and slide the plug up 2 Select the correct plug and slide it back into the power supply un l t...

Page 24: ...nent installa on This equipment is for use in a controlled environment Environmental situa on A Pollu on Degree 2 Al tude up to 2000 m Temperature 5 C to 40 C NOTE The Temperature icon will turn on if...

Page 25: ...irements of UN DOT 38 3 Tested by Shenzhen SEM Test Technology Co Ltd Reports STR16079052S 54S 10 2 2 EU Declara on of Conformity Please visit our website www monarchinstrument com to download our EU...

Page 26: ...arging Sta on for Nova Pro Li Ion Ba ery Packs Includes 115 230 Vac power supply with USA UK AUS Euro adapter plugs Charger Power Replacement power supply for use with Charging Supply Sta on 115 230 V...

Page 27: ...Laser Module Dock Part number 6281 021 AC Power Adapter 115 230 Part number 6281 015 Ba ery Charging Sta on Part number 6281 012 Standard Li ion Ba ery Pack Part number 6281 010 Hi Capacity Li ion Ba...

Page 28: ...ll rights reserved 1071 4241 113 0819 Handheld Tachometers Panel Tachometers Portable Stroboscopes Machine Vision Stroboscopes Check out our other product lines Speed Sensors Temperature Humidity Sens...

Reviews: