158 • Section 6 — Water Systems
Cayman 2006
Waste Pump (Optional)
The waste pump is a self-priming impeller pump designed to minimize clogging when draining the tanks. The
system comes with a 1 ½″ outlet hose with sewer pipe adapter and a 13 gallon per minute macerator pump.
To Empty the Black Tank:
• Ensure the connector on the macerator pump to the
termination point on the dump connection is secure. Ensure
waste pump outlet hose is secure.
• Remove the drip cap at the bottom of the sewer pipe adapter.
• Insert the adapter into the sewer connection.
• Open the solid (black) waste drain valve at the plumbing
service center.
• Turn on the macerator pump using the switch on the service
center panel.
• When the black tank is empty, turn off the pump.
To Flush the Black Tank:
• Ensure the sewer pipe adapter is inserted in the facility sewer
connection.
• Ensure the solid waste drain valve is open, the liquid waste drain valve is
closed and the grey tank is at least 50% full.
• Connect a non-potable water hose with pressure regulator to the fl ush
system fi tting in the plumbing service center. Turn on the water supply
and waste pump. Allow the water to rinse the black tank for at least three
minutes. Never operate the system unattended. Ensure the water fl ows
freely through the waste pump outlet hose.
• When completed turn off the faucet.
• Close the solid waste drain valve and open the liquid waste drain valve.
Turn on the waste pump. The water in the grey tank will fl ush the
remaining solids from the sewer hose. The liquid waste drain valve
remains open until the next drain cycle or time of departure.
When Preparing for Travel:
• Empty the tanks and close both the solid and liquid waste drain valves. Undo restraining devices from the
waste pump outlet hose. Drain the hose using a hand over hand method while working the hose toward the
shore connection. Remove sewer pipe adapter from shore fi tting and install drip cap. Coil and store hose in
water bay.
• If desired, add chemical to the tanks to control odor. Follow the directions given by the manufacturer of
the chemical.
NOTE:
Drain both waste tanks before traveling.
Troubleshooting:
• The house battery disconnect switch (in battery compartment) must be on to operate the macerator pump.
• 12 Volt DC power for the macerator pump is supplied by the house batteries and is protected with a 20
Amp mini breaker located in the battery bay in the electrical enclosure.
Inserting sewer pipe adapter into
sewer connection.
040517d
Sewer Pipe
Adapter
Drip Cap
Typical Dumping System Layout.
040543b
Summary of Contents for Cayman 2006
Page 12: ......
Page 20: ......
Page 22: ......
Page 24: ......
Page 59: ...Cayman 2006 Driving Safety Section 2 51 Weight Label 100179d ...
Page 65: ...Cayman 2006 Driving Safety Section 2 57 Actual Worksheet 020255b ...
Page 66: ...58 Section 2 Driving Safety Cayman 2006 Weight Record Sheet ...
Page 72: ...64 Section 2 Driving Safety Cayman 2006 NOTES ...
Page 74: ......
Page 106: ......
Page 132: ......
Page 156: ......
Page 174: ...166 Section 6 Water Systems Cayman 2006 NOTES ...
Page 176: ......
Page 190: ...182 Section 7 LP Gas Systems Cayman 2006 NOTES ...
Page 192: ......
Page 212: ...204 Section 8 Electrical Systems House Cayman 2006 NOTES ...
Page 214: ......
Page 232: ......
Page 287: ...Cayman 2006 Chassis Information Section 10 279 METRIC U S CONVERSION CHART ...
Page 289: ...Cayman 2006 Chassis Information Section 10 281 ...
Page 290: ...282 Section 10 Chassis Information Cayman 2006 ...
Page 291: ...Cayman 2006 Chassis Information Section 10 283 NOTES ...
Page 293: ...Cayman 2006 INDEX ...
Page 294: ......
Page 300: ...292 Index Cayman 2006 NOTES ...