21
d.1.3 Screen Lock
If you want to lock your thermostat’s screen, you can. You just have to choose
this option and then set a pattern with the small squares that appear on the
screen. To unlock the screen all you need to do is enter the pattern you setup.
d.1.2 Calibration
In the event of any disturbance, such as external heat sources, variations in the
temperature measurement may occur. Using this option, you can calibrate the
thermostat to counteract this effect.
The calibration may be configured between -9.9° and 9.9°.
d.1.1 Hysteresis
This term refers to the difference between the current (ambient) temperature
and the set target temperature (momit temperature), so that the heating and
cooling systems will switch on and off. It is the margin assigned to the momit
temperature to stop or start the HVAC system operating.
1 - Heat Mode: The ambient temperature at your home is 18° and you want to
reach 21.5 °. In this case, the boiler will be on until it reaches 21.5 °. After turning
off at 21.5 ° it will turn on immediately again when falling below 21,0º (0.5 ° C
below the target temperature).
2 - Cooling Mode: The ambient temperature at your home is 22º and you want to
achieve 18º. In this case the cooling system will be on until it reaches 18º. After 18
° it will turn on immediately again when rising to 18.5 ° (0.5 ° C above the target
temperature).
The hysteresis may be configured between 0.3° and 1.9°.