Page 6 of 32
TM03101 Molift Partner 255 Engelsk - Rev. F/ 11/2010
Service
Remove the battery before performing
maintenance on the lifter, to make sure
the lifter does not move unintentionally.
The Service lamp on the lifter will give a signal
when the lifter needs service. The Service lamp
will first give a yellow light, then red, meaning
thet service is required. If there is a sound to-
gether with the light, it means the lifter needs
service immediately.
Service lamp
Status
No light
Power save
Green
Ready for use
Yellow
Order service, lifter
still works
Red
Perform service
Red + sound
Perform service im-
mediately
Flashing yellow
Overheating
Service
Service is to be performed when the service
lamp gives a signal the first time (after approxi-
mately 10 000 normal lifts of 75 kg/12 sec) or
every 5th years.
• Lubricating and check of brake
• Changing of damaged and worn parts
Cleaning
Detergents must be pH-neutral. Do not
use solvents or strong liquids - this may
damage surfaces on the lifter and change
the quality of the material. For disinfec-
tion when needed; use isopropyl alcohol.
Avoid abrasive or etching cleaning prod-
ucts.
Clean surfaces with a damp cloth using an ap-
propriate detergent.
Troubleshooting
If the lifter does not work, check the power first.
Check that the battery lamp and service lamp
does not glow when pushing any button. See
the Troubleshooting table in Operator Manual.
If the troubleshooting procedure does not lead
to any diagnosis, judgement and eliminating
methods must be used.
Service lamp