molex MOD-Clip Installation Instructions Download Page 3

                                                                                                                                                                                                                                                                                                                   SHEET No. 

3

 of 

4

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

5.2.4

 While holding the jack against the wires push the Termination Head    to 

the left and pivot it 90° into the tool. Start to close the tool handles (Fig.11) 
Fully. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

NOTE: This tool does not have a full-cycle ratchet action 

– it is important 

for the operator to fully close the tool. 

 5.2.5

 

Release the tool handles to open the tool. The jack will remain in the 

Termination Head.

 

 

5.2.6

 Remove the terminated jack by pivoting the Wire Termination Head 90° 

and pulling the jack out of the wire comb. 

 

 

5.2.7

 Visually inspect the terminated jack for proper wire termination.            

The wires must be cleanly cut and fully seated to the bottom of the slots in the    
jack. Fig.12. 

   

  

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

  5.2.8 

Fit cable strain relief stuffer cap (Fig 13) 

 

 
  

 

 
 
 
 
 
 
 
 
 

 

 

     
 
 
 
 
     

 6

.

 MAINTENANCE

 

It is recommended that each operator of the tool be made aware of, and 
responsible for, the following maintenance steps: 

 1. Remove dust, moisture, and other contaminants with a clean  

   brush, or soft, lint free cloth. 

 2. Do not use any abrasive materials that could damage the tool. 

3. Make certain all pins, pivot points, and bearing surfaces are 

protected with a thin coat of high machine oil. Do not oil 

excessively. The tool is engineered for durability but like any 

other equipment it needs cleaning and lubrication for a 

maximum service life of trouble free termination. 

 4. Use light oil (30 weight automotive oil), at all the oil points,   

every 5,000 terminations or every 3months. This will significantly  

enhance the tool life.(Fig.14) 

 5. Keep oil away from the Wire Lacing Head and color code  

labels. Oil transferred from the wire termination area may affect  

 the electrical characteristics of the termination or cause color  

code labels to fall off. 

6. When tool is not in use, keep the handles closed and store the  

 tool in a clean, dry area 

 

 

Wires are fully 
seated 

and cleanly cut 
parallel 

Fig-12 

Fig-10 

Fig-13 

Fig-11 