                                                                                                                                                                                                                                                                                                                   SHEET No. 

2

 of 

4

 

      
 
5. TERMINATION PROCEDURE 

 

     Tools Required: 
         

  a) Cable Stripper 

              b) Wire clipper 
 
 

NOTE: The tool is designed to be used with Molex Premise Networks 
branded C5E and C6 U/UTP Cable. 

 
               

     5.1

 

Cable Preparation 

 

Remove 50mm (2”Inches) of cable 

sheath with cable stripper. Cut the 

central spline of the UTP cable back to 

                   the sheath. See Fig.5. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.2

Lacing Wires into the Termination Head.

 

Pivot the Termination Head 90° so the wire comb grooves face out from the tool. 
This is done by pushing the Termination Head to the left and pivoting it until it 
locks in place. See Fig.6. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.2.1

   

Place the prepared cable end in the slot of the Termination Head. (Fig. 7) 

 

 
 
 

5.2.2

.

 Untwist and lace wires into its respective comb groove in the            

Termination Head

 

 
 
 
 
 

 
 
 
 
 
Notes: 

1. Individual wires must be completely straightened inside the  

    Lacing head.(Fig. 8) 

2. Wires on side of the lacing head can remain twisted 

3. There are color code labels on the inside of the tool frame  

    for reference (Fig. 9) 

  

Jack Wiring Schematic 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

5.2.3

 

After all wires have been laced in the Termination Head, place the jack  

over the

 

Wires See Fig. 10.

 

   

 

 

 

 

4 CABLE PAIRS TO 
BE TERMINATED

 

CABLE 

LAID

 IN 

TERMINATION HEAD 

 

Fig-7 

Fig-5 

Fig-8 

Fig-9 

Fig-6 