SHEET No.
2
of
4
5. TERMINATION PROCEDURE
Tools Required:
a) Cable Stripper
b) Wire clipper
NOTE: The tool is designed to be used with Molex Premise Networks
branded C5E and C6 U/UTP Cable.
5.1
Cable Preparation
Remove 50mm (2”Inches) of cable
sheath with cable stripper. Cut the
central spline of the UTP cable back to
the sheath. See Fig.5.
5.2
.
Lacing Wires into the Termination Head.
Pivot the Termination Head 90° so the wire comb grooves face out from the tool.
This is done by pushing the Termination Head to the left and pivoting it until it
locks in place. See Fig.6.
5.2.1
Place the prepared cable end in the slot of the Termination Head. (Fig. 7)
5.2.2
.
Untwist and lace wires into its respective comb groove in the
Termination Head
Notes:
1. Individual wires must be completely straightened inside the
Lacing head.(Fig. 8)
2. Wires on side of the lacing head can remain twisted
3. There are color code labels on the inside of the tool frame
for reference (Fig. 9)
Jack Wiring Schematic
5.2.3
After all wires have been laced in the Termination Head, place the jack
over the
Wires See Fig. 10.
4 CABLE PAIRS TO
BE TERMINATED
CABLE
LAID
IN
TERMINATION HEAD
Fig-7
Fig-5
Fig-8
Fig-9
Fig-6