background image

Hand Crimp Tool for Sealed Single Contact Terminals 

Doc No: ATS-6382787HM  Release Date: 06-05-15 

UNCONTROLLED COPY

 

Page 4 of 9 

Revision: A 

Revision Date: 06-05-15 

TERMINAL 

PRE-STRIPPED 

WIRE WITH SEAL 

Figure 5 

WIRE STOP 

BLADE 

Figure 6 

WIRE 

INSULATION 

PUNCH 

CONDUCTOR 

ANVIL 

LOCATOR 

INSULATION ANVIL 

WIRES AGAINST 

LOCATOR STOP 

CONDUCTOR 

PUNCH 

TERMINAL 

SEAL 

SWING OPEN 

TERMINAL 

PUSH HERE TO 

OPEN WIRE STOP 

LOCATOR 

TERMINAL 

IN PLACE 

 

Figure 4 

LOCATOR LATCH 

IN OPEN POSITION 

 

Crimping Terminals 

1.

 

Crimp only the terminal listed in the preceding charts. 

2.

 

Turn the Locator Lock Latch down to unlock.  See Figure 3. 

3.

 

Swing the terminal locator away from the crimp tool shown in Figure 4. 

 

 
 
 
 

 
 
 
 

 
 
 
 

 

 

4.

 

Press down on the wire stop on the locator as shown in Figure 4.  Insert the terminal into the proper nest 
opening.  Make sure when choosing the nest opening, it will correspond with the correct profile on the hand 

tool. 

5.

 

Return the locator to closed position.   

6.

 

Turn the Locator Lock Latch up to lock.  Make sure that the terminal is visually centered over the punch. 

7.

 

Insert the proper wire (with the seal installed) over the terminal. 

8.

 

Gently touch the wire stop with the end of the wire and align the seal with the grips on the terminal. See Figure 5 
and 6. 

 
 

 
 
 
 

 
 
 
 

 
 
 
 

 

Note

: The tamper proof ratchet action will not release the tool until it has been fully closed. 

 

9.

 

Crimp the terminal by squeezing the tool handles until the ratchet mechanism cycle has been completed.  
Release handles to open the jaws. 

Summary of Contents for 63827-8700

Page 1: ... with simple contact positioning Easy handling due to outstanding force ratio Tool kits are easily installed into the Hand Crimp Tool or the 63816 0300 Power Crimp Head which is installed into the 63816 0200 110 V or the 63816 0250 220 V Battery Powered Tool Many different Tool kits can be used with a single Battery Powered Tool SCOPE Products Sealed Single Contact Terminal for S8 and T20 Socket T...

Page 2: ...minal Series No Wire Size Insulation Diameter Single Wire Seal Seal Crimp Crimp Height Crimp Width mm2 mm In Order No Color mm In mm In 49869 0 50 2 0 2 1 0 078 0 083 49454 9002 Red 3 80 4 00 0 150 0 157 4 20 4 40 0 165 0 173 0 75 1 7 1 9 0 067 0 075 0 85 2 1 2 3 0 083 0 091 Tool Qualification Notes 1 Pull Force should be measured with no influence from the insulation crimp 2 The above specificati...

Page 3: ...to the top slots of the nest Install the M4 x 18 long BHCS and tighten in place See Figure 1 Locator Installation and Removal Follow the steps below to install or replace the locator See Figure 2 To install the locator 1 Position the locator with the hole over the brass pivot shaft and snap it into place To remove the locator 1 Open the crimp hand tool 2 Swing the existing locator open and away fr...

Page 4: ...r away from the crimp tool shown in Figure 4 4 Press down on the wire stop on the locator as shown in Figure 4 Insert the terminal into the proper nest opening Make sure when choosing the nest opening it will correspond with the correct profile on the hand tool 5 Return the locator to closed position 6 Turn the Locator Lock Latch up to lock Make sure that the terminal is visually centered over the...

Page 5: ...oil excessively This tool was engineered for durability but like any fine piece of equipment it needs cleaning and lubrication for a maximum service life of trouble free crimping The use of light oil such as 30 weight automotive oil every 5 000 crimps or monthly will significantly enhance the tool life and ensure a stable calibration See Figure 7A or 7B for lubrication points 4 Store the tool in a...

Page 6: ...f this tool should be avoided Certification Molex does not certify or re certify commercial grade hand tools but rather supplies the following guidelines for customers to re certify hand tools This tool is qualified to pull force only To re certify crimp a terminal to a wire which has been stripped 12 7mm 1 2 long so there is no crimping of the insulation Pull the terminal and wire at a rate no fa...

Page 7: ...pplications for the Tool Kit Hand Crimp Tool Battery Powered Tool Figure 8 Figure 9 WARNING NEVER operate service install tool kits or adjust the Power Crimp Head without proper instruction and without first reading and understanding the instructions in the proper Manual or Specification Sheet See Chart above for the correct Manual or Specification Sheet WARNING NEVER install tooling or service th...

Page 8: ...ision A Revision Date 06 05 15 RATCHET RELEASE SCREW Figure 11 M4 X 8mm LONG BHCS 2 1 1 M4 X 18mm LONG BHCS M4 X 10mm LONG BHCS 2 3 WITH TOOL KIT LOCATOR ONLY HAND TOOL PARTS LIST Item Number Order Number Description Quantity 1 63810 1000 Hand Crimp Frame Long 1 2 63827 8770 Tool Kit with Locator 1 3 63827 8775 Locator only REF ...

Page 9: ...Y Page 9 of 9 Revision A Revision Date 06 05 15 Figure 12 1 2 2 M4 by 8 Long BHCS M4 by 18 Long BHCS M4 by 10 Long BHCS 1 POWER HEAD PARTS LIST Item Order No Engineering No Description Quantity 1 63816 0300 63816 0300 Power Crimp Head 1 2 63827 8770 63827 8770 Tool Kit 1 Visit our Web site at http www molex com ...