IDT Hand Tool
Doc No: ATS-638259900
Release Date: 05-24-13
UNCONTROLLED COPY
Page 4 of 6
Revision: A
Revision Date: 05-24-13
Assembly Inspection
After termination, the contacts must be seated to the dimension shown below:
Maintenance
It is recommended that each operator of the tool be made aware of, and responsible for, the following maintenance
steps:
1.
Do not use any abrasive materials that could damage the tool.
2.
Make certain all pins; pivot points and bearing surfaces are protected with a thin coat of high quality machine
oil. Do not oil excessively. The tool was engineered for durability, it needs cleaning and lubrication for
maximum service life. Light oil used at the pivot points every 5,000 terminations or 3 months, will significantly
enhance the tool life.
3.
Wipe excess oil from hand tool, particularly from the terminating area.
4.
When tool is not in use, keep the handles closed to prevent objects from becoming lodged in the termination
punch and store the tool in a clean, dry area.
Miscrimps or Jams
Should this tool ever become stuck or jammed in a partially closed position,
Do not
force the handles open or
closed.
The tool will open easily by pressing the ratchet release lever up. See Figure 9.
Tool Frame Preload
Tool frame preload is not available on this type of frame. The tool should be replaced when it fails to meet
assembly dimensions.
Warranty
This tool is for terminating individual wires into insulation displacement connectors only. All tools are warranted to
be free of manufacturing defects for a period of 30 days. Should such a defect occur, we will repair or exchange
the tool, free of charge. This repair or exchange will not be applicable to altered, misused, or damaged tools. This
tool is designed for hand use only. Any clamping, fixturing, or use of handle extensions voids this warranty.
CAUTION
: Molex specifications are valid only when used with Molex connectors and tooling.
Series:
93055, 93244, 93395
19
.3
+
/-
0.
2
19
.3
+
/-
0.
2
Series:
93065