LW005-MP
11 www.mokosmart.com
6.11 Default Power Status
When the LW005-MP is re-powered, users can configure the AC output of plug after power-up
according to different scenario applications:
➢
OFF: Configure the AC output to off, after LW005-MP is re-powered.
➢
ON: Configure the AC output to on, after LW005-MP is re-powered.
➢
Restore last mode: Configure the AC output to return to last state it was, after LW005-MP is
re-powered.
6.12 Bluetooth Configuration Tool
The device can use MKLoRa app developed by MOKO for quick OTA upgrades and parameter
configuration via Bluetooth connection. About the detail of MKLoRa, pls refer to LW005-MP APP
Guide.
The Bluetooth broadcast contents of LW005-MP are divided into advertising packet and response
packet. The following is an example of the broadcast content:
6.12.1 Advertising packet
LEN
TYPE
VALUE
2
0x01
0x 06
4
0x16
0x
04 AA
00
14
0x09
0x
4C 57 30 30 35 2D 4D 50 2D 35 43 33 42
⚫
Service UUID: LW005-MP (0x
04 AA
)
⚫
Device ADV Name: LW005-MP-5C3B (0x
4C 57 30 30 35 2D 4D 50 2D 35 43 33 42
)
(5C 3B is the last 4 bits of device MAC addresses)
6.12.2 Response packet
LEN
TYPE
VALUE
26
0xFF
0x
04 AA
DB 2B 3D 3A 5C 3B
09 03
00 59
00 00 00 72
37
C3
44
00 B4 1F 42
C2
00
⚫
Device MAC Address:
DB 2B 3D 3A 5C 3B
⚫
Voltage: 230.7V
(
0x 09 03
)
⚫
Current: 89mA (
0x 00 59)
⚫
Active power: 11.4W (
0x 00 00 00 72
)