Professional Motion 
Sensor Quartz Security 
Light for Canadian Tire

Model SL-5310

Features

•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).

Cover 

Plate

Sensor

3 Wire Nuts

6 Screws

(3 sizes)

Light Control

Cover Plate 

Gasket

© 2007 HeathCo LLC 

598-1327-01

Halogen

Bulb

Requirements

•  The light control requires 120-volts AC.
•  This fixture is designed for wall mounting only.
•  If you want to use Manual Override, the control must 

be wired through a switch.

• 

Some  codes  require  installation  by  a  qualified 
electrician.

•  This product is intended for use with the enclosed 

gasket and with a junction box marked for use in wet 
locations.

•  The backplate has knockouts so the sensor can be 

mounted on most junction boxes.

•  In some applications a universal adaptor plate may 

be needed. Adaptors are available at Home Centers 
and Electrical Supply Stores.

S-hook

OPERATION

* resets to Auto Mode at dawn.

TEST

TEST 1 5 10

ON-TIME

Put  the  ON-TIME  switch  on  the 
bottom of the sensor in the TEST 
position.

MANUAL MODE

ON-TIME

TEST 

1 5 10

... back on.

AUTO

1 Second OFF 

then...

Move ON-TIME Switch 

to 1, 5, or 10 minutes

Mode Switching Summary

Flip light switch 

off for one second 

then back on*

MANUAL MODE

AUTO

TEST

Note: When first turned on wait about 1 

1

/

2

 minutes for 

the circuitry to calibrate.

Manual  mode  only  works  at  night 
because  daylight  returns  the  sensor 
to AUTO.

Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.

Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5  or  10 
position.

*  If you get confused while switching modes, turn the 

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

This package includes:

Put the ON-TIME switch in the 1, 5 or 
10 minute position.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Normal

1, 5, 10 min.

x

Manual

Until Dawn*

x

Summary of Contents for SL-5310

Page 1: ...te may be needed Adaptors are available at Home Centers and Electrical Supply Stores S hook OPERATION resets to Auto Mode at dawn TEST TEST 1 5 10 ON TIME Put the ON TIME switch on the bottom of the sensor in the TEST position MANUAL MODE ON TIME TEST 1 5 10 back on AUTO 1 Second OFF then Move ON TIME Switch to 1 5 or 10 minutes Mode Switching Summary Flip light switch off for one second then back...

Page 2: ... an existing light with a wall switch for replacement Attach the lamp arm to the backplate arm and secure with the long bolt Note Whentighteningthearm screw pullonthewirestomake sure the wires are not pinched by the joint Remove the existing light fixture The S hook can be used to hold the fixture while wiring The small end of the hook can be inserted into a hole in the junction box The large end ...

Page 3: ...could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor Maximum Range Maximum Coverage Angle 8 ft 2 4 m 70 ft 21 m Least Sensitive Most Sensitive Sensor The detector is less sensitive to motion directly towards it 180 Turn the RANGE control to the mi...

Page 4: ...ively dark SYMPTOM Light stays on continuously Light flashes on and off Light flashes once then stays off in Manual Mode TROUBLESHOOTING GUIDE SYMPTOM Light will not come on Light comes on in day light Light comes on for no apparent rea son Light turns off too late in Dusk to Dawn setting POSSIBLE CAUSE 1 Light switch is turned off 2 Light is loose or burned out 3 Fuse is blown or circuit breaker ...

Page 5: ...ra MODO MANUAL préndalo 1 segundo APAGADO luego Mueva el interruptor de tiempo ON TIME a 1 5 ó 10 minutos Apague el interruptor por un segundo y préndalo de nuevo ON TIME TEST 1 5 10 Para AUTOMATICO Resumen de las modalidades del interruptor Para PRUEBA TEST 1 5 10 ON TIME Si se confunde mientras cambia de fases apague la electricidad por un minuto y préndala de nuevo Después del tiempo de calibra...

Page 6: ...es de la caja de empalmes con losalambresdelcontroldeluz Unalosyasegúrelos con un conector de alambre CUIDADO Para evitar los peligros de incendio o quemazón Deje que el elemento se enfríe antes de tocarlo La bombilla y el elemento funcionan a altas temperatu ras Mantenga al elemento por lo menos a 51 mm de los materiales combustibles No lo apunte hacia objetos que estén más cerca de 1 m Cambie só...

Page 7: ...1 m Evite apuntar del detector hacia Objetos que cambien rápidamente de temperatura tales como ductos de calefacción y acondiciona dores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales domésticos o el tráfico puedan activar el control Los objetos grandes cercanos y de colores res plandecientes que reflejan la luz del día pueden hacer que el detector se apague No ap...

Page 8: ...ida conti nuamente La luz se prende y se apaga La luz se prende una vez y luego permanece apa gada en la fase Manual SINTOMA La luz no se en ciende La luz se prende durante el día La luz se prende sin ninguna razón aparente La luz se apaga muy tarde en la calibración del Anochecer al Amanecer POSIBLE CAUSA 1 El interruptor de luz está apagado 2 El faro está flojo o fundido 3 El fusible está quemad...

Page 9: ...es 3 formats garniture de joint Crochet en S ESSAI Revient au mode automatique au lever du soleil FONCTIONNEMENT AUTOMATIQUE PRIORITÉ MANUELLE hors circuit pen dant 1 seconde puis à nouveau en circuit Placer l interrupteur ON TIME à 1 5 ou 10 minutes Mettre l interrupteur hors circuit pen dant une seconde puis le remettre en circuit Si vous ne savez plus dans quel mode se trouve l appareil couper ...

Page 10: ...e Pourfaciliterl installation choisirunappareild éclairage devant être remplacé et qui est déjà commandé par un interrupteur MONTER HORIZONTALEMENT Installation et remplacement de l ampoule Avant de remplacer l ampoule couper l alimenta tion et laisser refroidir le luminaire blanc blanc Raccorder le s fil s de terre du luminaire et la vis de terre de la plaque de garde au fil de terre de la boîte ...

Page 11: ...r modifier la zone de couverture Régler la sensibilité RANGE selon les be soins Une trop grande sensibilité pourrait cau ser des déclenchements intempestifs Pour une couvertureaccrue utiliser l amplification de portée Range Boost Fixer la tête du détecteur en position en serrant la vis de blocage Éviter de trop serrer la vis Placer l interrupteur ON TIME à 1 5 ou 10 minutes Vis de blocage Rotule P...

Page 12: ...liser un réglage de 3 h ou de 6 h SYMPTÔME Les lampes restent allumées continuellement Les lampes clignotent L éclairage clignote une fois puis reste éteint en mode manuel L éclairage s allume trop tard sous le réglage crépuscule aube SYMPTÔME Les lampes ne s allument pas Les lampes s allument le jour Les lampes s allument sans raison apparente CAUSE POSSIBLE 1 L interrupteurd éclairageestenpositi...

Reviews: