E32SUBC - CONTROLLER SETTING REFERENCE GUIDE
Entering programming modes
1. Hold the 'P' key for 3 seconds.
2. Display shows programming menu screen.
3. Scroll up/down to required and press P key to access.
4. Enter password as per below.
Service Settings
Password Pvr#2, Ov#3, Pvr#2, Pvr#3
Setting range
Default Setting
Temp offset Temp offset oven probe
+/-11
-1
Temp offset prover air probe
+/-11
+4
Temp offset prover water probe
+/-11
+2
Diagnostics Oven probe temp
displays current probe reading
Proofer probe air temp
displays current probe reading
Proofer probe water temp
displays current probe reading
Door switch Open/Close
displays door switch status
Float switch Open/Close
displays water tank float switch status
Humidity probe reading
displays current probe humidity reading
Oven heat relay output status
displays ON or OFF status
Oven power ON relay output status
displays ON or OFF status
Proofer heat relay output status
displays ON or OFF status
Proofer water heater relay output
status
displays ON or OFF status
Proofer power ON relay output status displays ON or OFF status
Oven fan realy output status
displays ON or OFF status