background image

OPERATIONS

INSTALLATION INSTRUCTIONS 

3

DRY TEST

ATTENTION:

To  insure  proper  operation,  before

installing  the  faucet,  a  “DRY  TEST”  is
recommended.

1.

Take off the control box lid 

(13)

by removing

screws 

(12)

with hex wrench. 

2.

Connect the sensor eye connector 

(20)

at the

end  of  the  sensor  eye  cable 

(18)

onto  the

circuit  board 

(24)

inside  the  control  box 

(10)

Refer to illustration “A”.

3.

Slide battery housing out of control box 

(10)

and  install  batteries  (included)  and  slide
battery  housing  back  into  control  box 

(10)

.

Insert the battery housing connector onto the
circuit board.  The lights on the circuit board
should blink red/green/red.  

4.

Place your hand in front of the sensor (23) to
operate  the  faucet  and  listen  for  a  “clicking”
sound.

5.

Remove  your  hand  and  listen  for  a  softer
“clicking”  sound.  The  “clicking”  sounds

indicate that the faucet is working properly. If
there  is  no  light  or  sound,  please  contact
Moen at 1-800-289-6636.

6.

The  sensors  are  equipped  with  angular
adjustments.  The  factory  setting  is  in  the
center  or  straight  position  from  the  faucet.
Adjustment  is  most  easily  performed  before
the  faucet  is  installed.  The  adjustment  is
located inside the faucet body 

(1)

behind the

LED  indicator  light 

(25)

Refer  to  illustration

“B”.

7.

If  you  are  ready  to  install  the  faucet,
disconnect the sensor eye connector 

(20

) at

the end of the sensor eye cable 

(18)

from the

circuit board 

(24)

.

8.

Attach supply rod 

(6)

into threads located at

the bottom of the faucet body 

(1)

. If needed,

snug  the  supply  rod 

(6)

with  a  “8  mm”  hex

wrench. Attach  compression  reducer 

(28)

to

the  supply  rod 

(6)

. Also  attach  compression

adapter 

(7)

to the solenoid valve outlet. 

9.

Attach  the  mounting  bolts 

(2)

to  the  faucet

body. If needed, snug mounting bolts 

(2) 

with

Phillips screwdriver. 

10.

Slide  gasket 

(3) 

over  sensor  eye  cable  and

onto faucet. 

11.

Set faucet on sink and install slotted washers

(4)

and mounting nuts 

(5)

. Tighten mounting

nuts 

(5)

to secure the faucet to the sink. 

12.

Connect the sensor eye connector 

(20) 

at the

end  of  the  sensor  eye  cable 

(18)

onto  the

circuit  board 

(24).

Properly  seat  both  the

sensor  eye  cable  seal  and  cable  into  the
control  box  slot  on  the  left.  Reinstall  control
box lid 

(13)

and tighten screws 

(12)

to insure

the  control  box  is  water-resistant.  NOTE:
make  sure  that  the  rubber  seal  plug  is  in
installed  in  the  AC  adapter  control  box  slot

(on the right).  

13.

Connect 3/8” copper tube (supplied) between
the  supply  rod  (6)  and  the  solenoid  valve

(17)

. Tighten compression fittings.

14.

Insert white nylon washer 

(9)

into swivel nut

on filter body inlet. 

15.

A) For standard (pre-tempered or cold water)

installation, attach water supply to inlet of
in-line filter/check valve body. 

B) If a tempered water installation is needed,

attach mixing/check valve (optional) to the
inlet  of  in-line  filter/check  valve  body.
Connect 

water 

supply 

lines 

to

mixing/check  valve.  Refer  to  illustration
“C”.  NOTE:  USE  THREAD  SEAL  TAPE
FOR ALL THREADED CONNECTIONS.

C) Refer  to  Illustration  D  for  the  optional

mixing tee installation.

16.

Turn  on  water  and  check  for  leaks.  Place
hand  in  front  of  sensor  to  activate  water.
Remove hands and the water should stop. If
not, refer to troubleshooting guide.

17.

For  timing  adjustments,  refer  to  instructions
on the inside of the control box lid.  Refer to
Illustration E.
A) Note:    Be  sure  to  depress  the  re-set

button,  located  on  the  circuit  board,  after
each adjustment.

B) The factory settings are:

Sensor Distance Adjustment =
approximately 3.5 inches from the lens
Time Delay to shut-off after hands are
removed = 1 sec seconds
Auto – shutoff  = 30 seconds

D

Sensor
Lens

Sensors

23

Sensor
Eye Cable

18

Optional
Supply
Tube
provided
by
installer

B

Compression
adapter

Optional
Supply
Tube
provided
by installer

Compression
adapter

C

Electronic Faucet

Operation and Installation
Instructions for Electronic
Faucets-Battery-Powered

The battery-powered faucet is designed for ease
of installation and provides a reliable, convenient,
economical and sanitary system for high-volume
users, such as hospitals, transportation terminals,
restaurants,  schools,  sports  arenas,  office
buildings and municipalities.  It can be installed by
one tradesman without electrical hook-up.

Operation:

1.

The faucet operates by emitting a continuous
infared beam from the sensor.

2.

As  the  user  enters  the  beam’s  effective
range, a red light flashes one time to alert the
user that the faucet will operate.  As long as
the user is in the beam’s range, the beam is
reflected  into  the  receiver  circuitry  and  the
system will operate.

3.

When the user exits out of range, the sensor
sends  a  signal  to  the  solenoid  for  closure.
The sensor then automatically resets and is
ready for the next user.

4.

Low  battery  indicator  light  comes  on  when
battery is low.

Caution

:    Avoid  installing  the  faucet  where

sensor  faces  a  stainless  steel  wall  or  other
reflective  surface  within  the  active  range  of
sensors.  Avoid facing another infrared sensor.  It
may cause faucet to activate unnecessarily. 

NOTE

:    The  reset  button  must  be  pressed

after changing the battery in order to ensure the
faucet functions properly. 

E

CONTROL BOX INSTRUCTIONS

ADJUSTMENTS: (DIP Switches):
1.

Shut-off time delay
after hands are removed:

Time Delay

SW1

SW2

SW3

1 Sec

on

on

on

2 Sec

on

on

off

3 Sec

on

off

on

4 Sec

on

off

off

5 Sec

off

on

on

6 Sec

off

on

off

7 Sec

off

off

on

8 Sec

off

off

off

2.

Auto Time-Out Feature:

Time-Out

SW4

SW5

0 Sec

on

on

15 Sec

on

off

30 Sec

off

on

60 Sec

off

off

3.

Sensor Distance:

Distance

SW6

3.5 – 12"

on

10 – 24"

off

4.

Faucet Setting:

Setting

SW7

SW8

Faucet

on

off

SENSOR DISTANCE ADJUSTMENT
(SDA): Preset at factory. If
adjustment is needed; Locate
potentiometer with Phillips Head
adjuster screw. Turn adjuster screw
clockwise to increase SDA, counter
clockwise to decrease SDA. 

AC/DC switch

Sensor
distance
adjustor

Reset
button

DIP
switches

Green
LED

DC receptor

Sensor
eye
cable pin
receptor

A

Circuit board
side view

Circuit board
front view

AC
receptor

Solenoid
pin
receptor

Red
LED

Summary of Contents for ELECTRONIC FAUCET 8301

Page 1: ...rformance Please read all instructions before installation Questions During Installation 1 800 BUY MOEN 1 800 289 6636 Toronto 905 829 3400 Rest of Canada 1 800 465 6130 TIPS FOR REMOVAL OF OLD FAUCET...

Page 2: ...montaje 2 Tuerca de montaje 2 Tubo de suministro Adaptador de compresi n Filtro en l nea Arandela Caja de control Aireador Tornillos 4 Tapa de la caja Sello de hule V lvula Check V lvula mezcladora 10...

Page 3: ...D SEAL TAPE FOR ALL THREADED CONNECTIONS C Refer to Illustration D for the optional mixing tee installation 16 Turn on water and check for leaks Place hand in front of sensor to activate water Remove...

Page 4: ...one time and water starts to flow Water stops when hands are removed Red indicator light stays on when battery is low NOTE The reset button must be pressed after changing the battery in order to ensur...

Page 5: ...OSCADAS C Vea la ilustraci n D para la instalaci n de la mezcladora T opcional 16 Abra la llave de agua y cheque las fugas Ponga la mano frente al sensor para activar la llave Cuando quite las manos e...

Page 6: ...so Algunos estados provincias y naciones no permiten la exclusi n o limitaci n de da os incidentales o consiguientes y por este motivo las sobrecitadas limitaciones posiblemente no le afectan Esta gar...

Page 7: ...UTILISER UN RUBAN POUR JOINTS FILET S C Voir l illustration D pour une installation optionnelle T avec mitigeur 16 Ouvrir l eau et v rifier s il y a des fuites Placer les mains devant l il du capteur...

Page 8: ...commercialisation ou d aptitude d utilisation Certains pays certains tats et certaines provinces ne permettent aucune exclusion ni limitation suite aux dommages indirects ou cons cutifs Les limitation...

Reviews: