background image

English

   19 

 

 

Please  inspect  the  following  before  contacting  the  Service  Center  in  the  event  of  operational 
disturbance: 

 

Problem 

Cause 

Solution 

 

Water is not hot or not cold.

 

 

-

 

Excessive dispensation of 
hot  water or cold  water in 
a short period of time. 

-

 

Unit  is  not  yet  connected 
to electricity.  

-

 

Wait 

until 

the 

water 

becomes cold or hot. 

-

 

Connect  the  cord  to  the 
outlet and press the heater 
and cooler switches.  

Water 

is 

not 

being 

dispensed out of the tap. 

-

 

Water gallon is empty. 

-

 

The  pipe  is  stuck  or 
blocks something. 

-

 

Replace  the  water  gallon 
with a new one 

-

 

Turn  off  the  switch  cooling 
to  4  hours,  and  then  turn 
the switch back. 

Leak  on  the  water  gallon 
support. 

-

 

Water  gallon  is  leaking  / 
damaged. 

-

 

Replace  water  gallon  with 
a new one. 

Loud noise during operation. 

-

 

Improper  installation  or 
placement of unit. 

-

 

Install  unit  on  even  and 
stable surface. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Part  6 

Problem & Solution

 

Summary of Contents for DD 02

Page 1: ...12 16 www modena co id DD Series BUKU PETUNJUK PENGGUNAAN DISPENSER DAN KARTU GARANSI WATER DISPENSER MANUAL AND WARRANTY CARD ...

Page 2: ...n rinci sehingga memudahkan Anda dalam menggunakan dan memanfaatkannya Agar produk dispenser ini dapat berfungsi normal dalam jangka waktu yang panjang kami sangat merekomendasikan agar buku ini tidak saja menjadi pegangan Anda sebagai pembeli namun juga sebagai panduan bagi siapa saja yang menggunakan dan mengoperasikannya sehingga keawetan dan kualitas fungsionalnya lebih tahan lama Buku ini san...

Page 3: ...HLM Kata Pengantar 1 Bagian 1 Nama nama Bagian 3 Bagian 2 Instalasi 6 Bagian 3 Cara Penggunaan 6 Bagian 4 Pemeliharaan 7 Bagian 5 Tindakan Pencegahan 7 Bagian 6 Masalah Solusinya 9 Bagian 7 Spesifikasi 10 NOMOR P 6 INDO2 00301 0212 ...

Page 4: ...u indikator 10 Sakelar merah pemanas 4 Tombol keran air dingin 11 Kabel listrik 5 Tombol keran air normal 12 Lubang pembuangan air 6 Tombol keran air panas 13 Kondensor 7 Wadah untuk menampung air 14 Timer sterilizer Khusus DD12 DD 32 dengan kabinet bawah pendingin DD 12 dengan kabinet bawah sterilizer DD 02 tanpa kabinet bawah Bagian 1 Nama nama bagian ...

Page 5: ...as 9 Sakelar hijau pendingin 3 Lampu indikator 10 Sakelar merah pemanas 4 Tombol keran air dingin 11 Kabel listrik 5 Tombol keran air normal 12 Lubang pembuangan air 6 Tombol keran air panas 13 Kondensor 7 Wadah untuk menampung air 14 Timer sterilizer DD 16 dengan kabinet bawah sterilizer DD 06 tanpa kabinet bawah ...

Page 6: ...in sterilizer 2 Tombol air normal 10 Sakelar hijau pendingin 3 Tombol air dingin 11 Sakelar merah pemanas 4 Penyangga botol 12 Kabel listrik 5 Penutup atas 13 Lubang pembuangan air 6 Lampu indikator 14 Kondensor 7 Keran keluar air 8 Wadah untuk menampung air DD 03 tanpa kabinet bawah ...

Page 7: ...ntuk mengeluarkan air dingin tekan tombol keran pada bagian kanan Cara menggunakan lemari pendingin khusus Dispenser dengan ruang pendingin Jangan meletakkan makanan minuman pada saat pertama kali penggunaan dispenser sampai dengan alat bekerja selama 2 jam Makanan yang panas harus didinginkan sampai dengan suhu ruang sebelum dimasukkan ke dalam lemari pendingin Berikan cukup ruang di dalam lemari...

Page 8: ...ngin dengan menggunakan kain lembut yang kering atau spon setiap tujuh hari sekali atau jika air defrost sudah tampak penuh 1 Letakkan dispenser di permukaan yang rata Hindari meletakkannya di tempat yang lembab Berikan jarak sedikitnya 20 cm dari dinding Dan jangan meletakkan benda benda yang mudah terbakar di dekat dispenser 2 Untuk menghindari kerusakan pada mesin jangan menghubungkan kabel lis...

Page 9: ...kabel listrik haruslah dilakukan oleh tenaga yang berpengalaman dan sangat mengerti akan kelistrikan Jangan pernah mengganti sendiri kabel listrik dikarenakan akan bisa menyebabkan bahaya yang bisa merugikan diri sendiri dan orang lain Perhatian Produk ini tidak boleh dibuang bersama sampah rumah tangga lainnya Untuk mencegah kemungkinan bahaya terhadap lingkungan atau kesehatan manusia akibat pem...

Page 10: ...enjadi panas atau dingin Hubungkan steker ke stop kontak kemudian tekan sakelar pemanas dan sakelar pendingin Tidak ada air yang keluar dari keran Galon air kosong Pipa terhalang atau tersumbat sesuatu Ganti dengan galon air yang baru Matikan sakelar pendingin sampai 4 jam kemudian nyalakan kembali sakelar pendingin Terdapat kebocoran pada penyangga galon air Galon air bocor rusak Ganti dengan gal...

Page 11: ...u abu G Putih W Output air panas liter jam 2 5 2 5 2 5 Output air dingin liter jam 2 2 2 Kapasitas tangki air panas liter 0 8 0 8 0 9 Kapasitas tangki air dingin liter 1 5 1 5 2 Suhu panas celcius 90 90 90 Suhu dingin celcius 10 10 10 Kompresor bebas CFC Ya Ya Ya Anti Tumpah Ya Ya Ya Thermostat pengatur suhu air Ya Ya Ya Bahan dari tabung air Stainless Stainless Stainless Daya listrik pemanas watt...

Page 12: ......

Page 13: ...nual to facilitate the users In order for this water dispenser to perform normally for an extended period of time we highly recommend not only the buyer to hold onto this manual but also those who wish to operate the product optimally to maintain its service period and quality This manual is recommended for use by anyone who operates the water dispenser We also provide a customer care service for ...

Page 14: ...ish 12 CONTENTS PAGE Introduction 11 Part 1 Name of Parts 13 Part 2 Installation 16 Part 3 How to Use 16 Part 4 Maintenance 17 Part 5 Precaution Action 17 Part 6 Problem Solution 19 Part 7 Specification 20 ...

Page 15: ...witch refrigrator 3 Indicator lamp 10 Red switch heater 4 Cold water tap button 11 Cable power 5 Normal water tap button 12 Water drainage 6 Hot water tap button 13 Condensor 7 Water container 14 Timer sterilizer Specifically DD12 DD 32 with lower cabinet refrigerator DD12 with lower cabinet sterilizer DD02 without lower cabinet Part 1 Name of Parts ...

Page 16: ...lizer door 2 Top cover 9 Green switch refrigrator 3 Indicator lamp 10 Red switch heater 4 Cold water tap button 11 Cable power 5 Normal water tap button 12 Water drainage 6 Hot water tap button 13 Condensor 7 Water container 14 Timer sterilizer DD16 with lower cabinet sterilizer DD06 without lower cabinet ...

Page 17: ...rator sterilizer door 2 Normal water button 10 Green switch refrigrator 3 Cold water button 11 Red switch heater 4 Bottle support collar 12 Cable power 5 Top cover 13 Water drainage 6 Indicator lights 14 Condensor 7 Water spigot 8 Water container DD 03 without lower cabinet ...

Page 18: ...central button tap To dispense cold water push the right button tap How to use refrigerator for Dispenser with built in refrigerator Do not store food drink until after 2 hours of dispenser usage Hot food must be cooled down to room temperature before stored in the refrigerator Provide adequate space in the refrigerator to make sure that air is circulating well How to use sterilization cabinet for...

Page 19: ... using dry cloth or sponge once every seven days or when the defrost water is filling up 1 Install the dispenser on even surface Avoid storing in humid place Provide a minimum of 20 cm of distance from the wall and do not store flammable substances near the dispenser 2 To avoid damage to the machine avoid connecting electrical cord or pressing hot water switch red until the water can flow out of h...

Page 20: ...r MODENA to do the replacement Replacement power cord must be done by experienced personnel and understand about electricity Never replace the power cord itself due to the dangers that could lead to harm themselves and others Attention This product must not be disposed of with other household waste To prevent possible harm to the environment or human health from uncontrolled waste disposal The uni...

Page 21: ...hot Connect the cord to the outlet and press the heater and cooler switches Water is not being dispensed out of the tap Water gallon is empty The pipe is stuck or blocks something Replace the water gallon with a new one Turn off the switch cooling to 4 hours and then turn the switch back Leak on the water gallon support Water gallon is leaking damaged Replace water gallon with a new one Loud noise...

Page 22: ...W Hot water output liter hour 2 5 2 5 2 5 Cold water output liter hour 2 2 2 Hot water tank capacity liter 0 8 0 8 0 9 Cold water tank capacity liter 1 5 1 5 2 high temperature celcius 90 90 90 Cold temperature celcius 10 10 10 Free CFC compressor Ya Ya Ya Anti spill Ya Ya Ya Water temperature regulator thermostat Ya Ya Ya Water tube material Stainless Stainless Stainless Power Hot watt 200 200 20...

Page 23: ......

Reviews: