17
MODEL TRAIN TECHNOLOGY ™
the device is powered and animation is activated. It doesn’t know
what time of day it is.
•
Fade = 50. If you set a port to Fade using the preprogrammed value
of 50, it will disable the Fade timer for that pin but set the pin to fade
on command. This allows you to have a Fade effect on ports that
you control only via DCC. To return the port to an active timer,
select either “5” or any other 50’s value (like 51) other than “50”.
Think of the zero of the 50 as “off”.
•
Welding 1,2 and 3 use different time gaps between activity. 1 is the
shortest and 3 is the longest. Combine these on different Ports so
that one activity FX is the white-hot arcing and the longer period
could be a RED led meant to show the red-Hot arcing.
•
Lighting – setting them Mode to 16 follows the value in CV 125 which
is a 1-minute delay by default. Lighting 17 divides this by
½
and
Lighting18 doubles the value.
•
The Step FX turns on and off LEDs in sequence starting at Port 1 (if it
is set to a 7 series) through to 16. It will skip Ports that are not set to
a 7 series 71-79)
o
The Race sequence repeats by starting at 1
o
The Chase sequence repeats by going backward from 16, then
forward at 1, so back and forth.
o
Each LSC II can either Race or Chase but not both
simultaneously.
•
DCC Signal Scan is the amount of time that the LSC II waits after
power on to switch into animation mode if it does not detect a DCC
Signal. You can select ANY Port since it affects the entire device,
select the value for the delay option and press SAVE. The previous
FX behavior for that Port will NOT change.
To see the effect, you must switch OFF the LSC II. After it’s start up
cycle you will be able to detect a change in time that it takes to start