B
A
C
D
E
F
G
SER
VICE
59
5. Press the large power button in the middle of the remote control to exit the test mode and return
to normal operation. The remote should only be displaying the time. Check the fire will start using
the remote control by pressing the large power button. Turn it off again using the remote control.
6. The fire is now linked to the remote control.
S6 Replacing the Burners
The burners are specific to the different fuelbed options. For standard fuel beds (coals, crystalight/
gems, logs, or woodland) see “E4 Placing the Infill & Burners” on page 25.
S7 Serial Number
The serial number for the fire can be found in two places. The first is in the battery compartment of
the wireless remote under the batteries. The second is on the data sticker on the chassis under the
electronics tray.
S8 Removing or Cleaning Fan
As part of regular service procedure, it is recommended that the fan is removed for cleaning. Dust
will build up on the fan rotor and in the cavity where the fan is located. This can be removed by the
service person using a hearth brush and a vacuum cleaner.
ISOLATE THE POWER TO THE FIRE BEFORE STARTING THIS PROCEDURE.
Remove the glass, outer trims, infill and burners - following sections “Removing (and Replacing)
the Glass” on page 24 & “Placing the Infill & Burners” on page 25. Then unravel the LED
light strip in the direction highlighted below to gain access to the fan assemblies.
Remove the six screws holding the fan assembly in place and lift out using the handles.
Screw Locations: