MobileView 7000 Series User Manual
48
Z
: This is defined as top to bottom on the device (+1G is normal)
Opening the G Sensor Menu
1. After opening the Status menu, select
G Sensor
to open the G sensor status.
2. The status displays, automatically updates, and cannot be changed.
G Sensor Menu
Alarm Menu
The alarm status menu dynamically displays the current state of digital and analog inputs monitored
by the device.
Digital
: Monitored input is physically inactive/OFF (L) or active/ON (H)
Analog
: Current voltage level of monitored input (range = 0VDC – 30VDC)
CAUTION:
Digital and analog inputs use a voltage range input. Each has expected operational
values and maximum allowed values as shown.
Digital Input
o
Inactive/OFF State
: 0VDC – 5VDC
o
No State Guarantee: 5VDC – 6VDC
o
Active/ON State: 6VDC – 36VDC
o
Max allowed voltage = 40VDC
Analog Input
o
Voltage Range: 0VDC – 36VDC
o
Max allowed voltage = 40VDC
Opening the Alarm Menu
1. After opening the Status menu, select
Alarm
to open the alarm status.
2. Alarm status displays and cannot be changed. The status automatically updates.