![Mobeye CM2410 Manual Download Page 22](http://html1.mh-extra.com/html/mobeye/cm2410/cm2410_manual_1814823022.webp)
19
9. USE OF EXTERNAL POWER SUPPLY
Although the Mobeye CM2410 is designed to run on batteries, it is possible to use
an external power supply. In this mode the module is always in connection with the
GSM network and therefore always in program mode. In case the power fails, the
batteries take over the functioning. The module continues operating albeit in the low
power mode. This means the GSM module switches off and only establishes
network connection in case it needs to send out an alarm, test message or low
battery alert.
Connect the external power adapter (12VDC) to
the power input of the connector (press on the
green pins for connecting the wires):
-
V+ to “+”
-
Ground (black lead) to “-“