© MOBATIME
8 / 16
800945.06
control PCB (DC user manual chapters 2.8, 2.9). Check the marking of the jack-
plugs, in order to prevent their mix-up.
•
Connect the interconnecting cables into the corresponding terminals on the clock
control PCB including the 10-core flat cable. Reconnect the earth wire to connect
the clock body to the front panel.
•
Connect the 10-core interconnecting cable into the corresponding plug on the
clock control PCB.
•
Put the control front panel to the clock body. Care should be taken when placing
the cables between the clock body edge and the back side of the control front
panel, so as not to nip them.
SLH-DC..D.S
cut
2.3 Ceiling and side mounting single-sided stainless-steel clock
•
The single-sided clock consists of two parts, one front panel and stainless-steel
clock body with connecting terminal block. The front panel is held together by
neodymium magnets.
The clock suspension part is delivered separately.
•
Pull the incoming conductors through the pipe which serves as the clock
suspension. Fix the ceiling suspension (or the side console) to the ceiling (or the
wall), using 4 appropriate screws of 5 mm diameter. Use dowels if necessary.
•
Remove the front panel from the clock body. The panel is held by magnets,
you need to use a relatively high force to remove it.
•
Disconnect the interconnecting cables by decoupling the terminals on the control
PCB. Disconnect the earth wire connecting the clock body to the front panel.
•
Pull the incoming conductors through the pipe insert in the clock body. Slip-on the
clock body onto the suspension in a way that the screws fit into the lower groove
on the pipe insert. Fix the connection by tightening the screw using an allen key.
•
On mains powered clock loosen the screw on the underside of the 230 VAC
terminal cover and remove the cover. Unscrew the cable clamp.