background image

© MOBATIME 

12 / 16 

800945.06 

 

16 

Engineering data 

16.1 

Standard design of the clock 

 

 

Specification 

 

SL

H

-D

C

.57

.4

 

 

SL

H

-D

C

.57

.4

.2

 

 

SL

H

-D

C

.57

.6

 

 

SL

H

-D

C

.57

.6

.2

 

 

SL

H

-DC

.57

x.6

 

 

SL

H

-D

C

.57

x.

6.

 

SL

H

-D

C

.10

0.

 

SL

H

-D

C

.10

0.

 

SL

H

-D

C

.10

0x

.6

 

 

SL

H

-OPD

 

 

SL

H

-OP

 

 

height of the digits [mm] 

57 

57 

57/38 

57/38 

57 

57 

100 

100 / 57 

100 

38 

Display 

number of digits 

4+2 

4+2 

4+2 

number of lines 

 

 

Time/Date display 
format 

HH : MM 
DD.MM 

✓ 

✓ 

 

 

 

 

✓ 

 

 

 

HH : MM.

SS 

DD. MM.

YY 

 

 

✓ 

✓ 

 

 

 

✓ 

 

 

HH : MM : SS 
DD. MM.YY 

 

 

 

 

✓ 

✓ 

 

 

✓ 

✓ 

 

 

Powering 

standard 

100 - 240 VAC, 50 - 60 Hz 

MOBAline / 

Impulse 

VDC (on request) 

18

56 VDC (18

40 VAC) 

PoE variant (IEEE 802.3af) 

1 LAN input 

2 LAN 

inputs  1 LAN input 

 

 

Power consumption 

[VA] 

single sided, mains powered 

11 

16 

16 

10 

0,15 

double sided, mains powered 

11 

16 

16 

11 

16 

18 

single sided, PoE 

11 

15 

15 

10 

double sided, PoE 

11 

15 

15 

11 

15 

15 

 
Crystal timebase 

passive running reserve 

(time + date) 

 

6 years (except PoE) 

running reserve PoE version 

12 hours 

accuracy 

+/- 0.1 s / day without synchronization (after 24 hours of synchronization at constant temperature) 

Accuracy of 
temperature 
meassurement 

range -

10 ÷ +85 °C

 

±0,5 °C

 

range -

50 ÷ +125 °C

 

±2,0 °C

 

 

Operating 
environment 

temperature 

-

5 ÷ +50 °C

 

humidity 

0 - 95%, (without condensation) 

protection degree 

IP 54 

Weight [kg] 

(without mounting 
bracket) 

single sided N.N 

2,6 

3,3 

3,5 

5,5 

4,7 

5,8 

6,5 

single sided N.S 

2,6 

3,3 

3,5 

5,5 

4,7 

5,8 

6,5 

double sided D.S 

5,5 

7,3 

10 

flush mounting N.F 

2,6 

3,3 

3,5 

5,5 

4,7 

5,8 

6,5 

 
 
 
 
 
 
 

 

Dimensions [mm] 
(W x H x D) 

 

single sided N.N 

360 
150 

65 

360 
260 

65 

450 
150 

65 

450 
260 

65 

480 
150 

65 

480 
260 

65 

555 
220 

65 

695 
220 

65 

770 
220 

65 

350 
440 

48 

350 
350 

48 

 

single sided N.S 

360 
150 

65 

360 
260 

65 

450 
150 

65 

450 
260 

65 

480 
150 

65 

480 
260 

65 

555 
220 

65 

695 
220 

65 

770 
220 

65 

 

 

 

double sided D.S 

360 
150 

95 

 

450 
180 

95 

 

480 
150 

95 

 

555 
220 

95 

695 
220 

95 

770 
220 

95 

 

 

 

flush mounting N.F 

380 
170 

62 

380 
280 

62 

470 
170 

62 

470 
280 

62 

500 
170 

62 

500 
280 

62 

555 
220 

62 

695 
220 

62 

770 
220 

62 

350 
440 

75 

350 
350 

75 

flush mounting back cover 
dimension W1 x H1 

340 
129 

320 
236 

430,5 

129 

430,5 

236 

461 
129 

461 
236 

516 
180 

658 
180 

733 
180 

308 
398 

308 
308 

dial diameter 

248 

248 

Summary of Contents for SLH-DC series

Page 1: ...MOBATIME BE 800945 06 INSTRUCTION MANUAL State of the art technology digital clock SLH DC series addition to the standard DC series instruction manual for SLH DC only...

Page 2: ...order to explain all details in respect of the operation of the product Should you nevertheless have questions or discover errors on this manual please contact us 3 We do not answer for direct or ind...

Page 3: ...single sided stainless steel clock 8 2 4 Flush mounting single sided stainless steel clock 9 2 5 Connecting terminal block 11 16 Engineering data 12 16 1 Standard design of the clock 12 16 2 Voltage...

Page 4: ...ion thanks to magnetic system easily washable with water high resistance to washing disinfectants anti glare polycarbonate front glass prevents glare and improves readability dust proof housing splash...

Page 5: ...cified value with stop at zero with automatic restart or counting into negative values display of intermediate time values freezing of display cumulated intermediate time counting in steps of 1 minute...

Page 6: ...e clock body to the wall On mains powered clock loosen the screw on the underside of the 230 VAC terminal cover and remove the cover Unscrew the cable clamp Connect the incoming conductors in accordan...

Page 7: ...front panel from the clock body The panel is held by magnets you need to use a relatively high force to remove it Disconnect the interconnecting cables by decoupling the terminals on the control PCB D...

Page 8: ...terminal block The front panel is held together by neodymium magnets The clock suspension part is delivered separately Pull the incoming conductors through the pipe which serves as the clock suspensio...

Page 9: ...ng terminals on the control PCB DC user manual chapters 2 8 2 9 Check the marking of the jack plugs in order to prevent their mix up Connect the interconnecting cables into the corresponding terminals...

Page 10: ...appropriate shape or cut them off to a length that will not obstruct the placement of the front part of the clock into the clock body On mains powered clock mount the 230 VAC terminal cover back and s...

Page 11: ...MOBATIME 11 16 800945 06 SLH DC N F wall niche mounting cut 2 5 Connecting terminal block terminal block for NTP and WiFI version terminal block for remaining version except PoE...

Page 12: ...ut synchronization after 24 hours of synchronization at constant temperature Accuracy of temperature meassurement range 10 85 C 0 5 C range 50 125 C 2 0 C Operating environment temperature 5 50 C humi...

Page 13: ...yboard SKH SKW SKF SKF back cover dimension W1 x H1 Dimensions mm W x H x D 80 x 180 x 42 4 120 x 120 x 47 82 x 152 x 50 67 x 139 Type of slave line Voltage range Electric current consumption MOBALine...

Page 14: ...on t use synthetics 19 DISPOSAL OF USED BATTERIES The user is lawfully obligated to return unusable batteries Disposal of used batteries through household waste is prohibited Batteries which contain d...

Page 15: ...ent according to the corresponding norm The following circumstances are excluded from the guarantee inappropriate handling or interventions chemical influences mechanical defects external environmenta...

Page 16: ...ch www mobatime ch MOSER BAER SA EXPORT DIVISION 19 ch du Champ des Filles CH 1228 Plan les Ouates Tel 41 22 884 96 11 Fax 41 22 884 96 90 export mobatime com www mobatime com MOSER BAER AG Spitalstra...

Reviews: