© MOBATIME 30/36
BE-801259.03-HN 60&61master clock
10 STRIKING
This function is used to set the parameters and type of striking, for rack version only.
In the MAIN Menu press the button to select Striking.
Options:
22-05
setting of the beginning and end of the time period when the striking is
switched off; e.g. at setting 22-06 the last hit is at 22:00 and the striking
starts the next day at 6:00
1/2
adjusting the type striking; the choice is 1/2, 1/4, and off
I
enter the pulse length in tenths of a second (01-99)
P
enter the pulse gap length (01-99)
Ph
enter the length of the gap between the
¼ and the hour striking (01-99)
Button functions:
move between the items
change the blinking item
save the entered values and return to MAIN menu
return to MAIN menu without saving