MMD Equipment PowerPro IGR6000H Owner'S Manual Download Page 1

Owners Manual

IGR6000H

Inverter Generators

PowerPro

MMD Equipment

4175 Guardian Street  •  Simi Valley, CA 93063 

602 Dunton St.  •  San Antonio, TX 78226

2075 High Hill Road  •  Logan Township, NJ 08085

www.mmdequipment.com

Phone: 800-433-1382

Fax: 800-225-5579

Summary of Contents for PowerPro IGR6000H

Page 1: ...Inverter Generators PowerPro MMD Equipment 4175 Guardian Street Simi Valley CA 93063 602 Dunton St San Antonio TX 78226 2075 High Hill Road Logan Township NJ 08085 www mmdequipment com Phone 800 433...

Page 2: ...Reference For your reference please record the model serial number see page 9 sales representative and date of purchase Model _____________________________________________________________ Serial ____...

Page 3: ...damage if instructions are not followed Provides helpful information 1 Safety Instructions This generator is designed to provide safe and dependable service if operated according to instructions n Rea...

Page 4: ...s representative for a replacement CARBON CANISTER CONTROL PANEL AIR INTAKE AIR EXHAUST HIGH TEMPERATURE LABEL FUEL LEVEL INDICATOR FUEL FILLER CAP AIR FILTER SPARK PLUG OIL CAP SERVICE DOOR n Always...

Page 5: ...CEPTACLES CHOKE KNOB SMART THROTTLE SWITCH Serial Number Identification and Location The engine serial number is stamped on the engine block to the left of the oil drain plug In most cases the battery...

Page 6: ...ect the oil level and refill regularly OIL LEVEL INDICATOR OIL DRAIN BOLT 2 Check the fuel level a Fuel tank capacity is 5 9 gal 22L b Use automotive unleaded 87 octane gasoline only Do not use premiu...

Page 7: ...t contains more than 10 ethanol Do not use gasoline containing methanol n Fuel system damage or engine performance problems resulting from the use of fuels that contain an improper alcohol blend are n...

Page 8: ...for the first time or after long term storage or after running out of fuel turn the fuel valve lever to the ON position then wait for 10 to 20 seconds before starting the engine 4 Starting Procedure a...

Page 9: ...rs or others who contact the lines during a power outage When utility power is restored the generator may explode burn or cause fires in the building s electrical system n Do not connect the generator...

Page 10: ...loading that continuously lights the overload indicator light red may damage the generator Marginal overloading that temporarily lights the overload indicator light red may shorten the service life of...

Page 11: ...transformers Output voltage is 15 30V DC output will vary according to the position of the Smart throttle switch 1 Connect the charging cable to the DC receptacle of the generator and then to the batt...

Page 12: ...ating temperature before applying the air conditioning load Always allow a 2 minute wait period when manually cycling an air conditioner off and on n A longer wait period may be required under unusual...

Page 13: ...uretor air fuel mixture will be excessively rich Performance will decrease and fuel consumption will increase High altitude performance can be improved by installing a smaller diameter main fuel jet i...

Page 14: ...to use the EPA standard accessories Emission control system Emission source Exhaust gas contains carbon monoxide nitrous oxide NOx and hydrocarbons It is very important to control the emissions of NOX...

Page 15: ...fornia certified models CARB requires that an air quality index label be attached to every certified engine showing the engine emission information for the emission duration period The label is provid...

Page 16: ...DRAIN BOLT UPPER LIMIT LOWER LIMIT 2 AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor To prevent carburetor malfunction service the air cleaner regularly Service more...

Page 17: ...by hand it should be tightened 1 2 turn with a wrench to compress the sealing washer If a used plug is being reinstalled it should only require 1 8 to 1 4 turn after being seated i Reinstall the spark...

Page 18: ...itions n Do not smoke or allow flames or sparks in the area 3 Change the engine oil see page 30 DRAIN PLUG 4 Spark plug and engine a Remove the spark plug and pour about a tablespoon of clean engine o...

Page 19: ...ank Refuel with gasoline Fuel switch not on Turn fuel switch to ON position Not enough oil in engine Refill with recommended oil Fuel not reaching carburetor How to check 1 Turn off fuel valve and loo...

Page 20: ...MMD WILL PAY FOR MINOR ADJUSTMENTS FOR A PERIOD OF NINETY DAYS FROM THE INSERVICE DATE OF THE GENERATOR MMD DENIES ANY RESPONSIBILITY FOR LOSS OF TIME OR USE OF THE PRODUCT TRANSPORTATION COMMERCIAL...

Page 21: ...ntrol system warranty on your 2011 and later small off road engine SORE In California new SOREs must be designed built and equipped to meet the State s stringent anti smog standards MMD Equipment must...

Page 22: ...016 Curved hose Bracket Fixed frame Bolt Connected to air filter Vent hose Fuel hose Fuel switch Fuel tank Filter screen Fuel cap Certificate No X680BM Q 08 006 Carbon canister 650cc Carbon canister l...

Page 23: ...______________________ Model Number_______________________________________________ Serial Number_______________________________________________ Sales Representative____________________________________...

Page 24: ...MMD PowerPro Inverter Generators IGR6000H 091615 Page 46 Notes Notes...

Page 25: ...Rev 2 09165 Scan for MMD technical support MMD Equipment 4175 Guardian Street Simi Valley CA 93063 602 Dunton St San Antonio TX 78226 2075 High Hill Road Logan Township NJ 08085 www mmdequipment com P...