User Guide for Mobile Devices with iOS v. 10.3 

 

 

 

Summary of Contents for Midor

Page 1: ...Midor Balancing Measuring Device User Guide for Mobile Devices with iOS v 10 3...

Page 2: ......

Page 3: ...9 Measuring Context Menu Tabs 10 Select Valve 10 Valve Preset 11 Medium 11 Kv Direct Setup 11 Set Requested Flow 12 Medium Temperature 12 Pressure Measuring Zero Deaeration of Measuring Hoses 13 Proj...

Page 4: ...Items Tab 22 Heating Engineering Calculations 22 Preset Calculation 23 Pressure Loss Calculation 24 Available Pressure Calculation 24 Valve Authority Calculation 25 Maintenance 26 Sintered Filters Rep...

Page 5: ...ction with a built in symmetrical differential sensor for accurate digital processing of measured data The Midor measuring instrument is very accurate and this accuracy is based on Very accurate measu...

Page 6: ...stored in the mobile device s storage The application stores in the mobile device s storage balancing valves of most leading European producers If incidentally a valve in not contained in the applica...

Page 7: ...ther you can turn on off here the sound for the whole Midor application Turn on off the sound in the Midor application by pressing the Sound button In the Records section you can enter Initial descrip...

Page 8: ...the NiMH type Well known and of high quality are Eneloop batteries from Panasonic Pressure Unit Turn on Warning Very important When switched on the instrument initialises itself This take several seco...

Page 9: ...for any other Once the Measuring button is pressed the Measuring screen will appear straight away You can cancel the Always use the selected device from the Application Setup the Sensor Preferences Al...

Page 10: ...ed in the Midor instrument database will open from which you select the manufacturer required by you The database of valves in the instrument contains valves the world s leading manufacturers When sel...

Page 11: ...col ant freeze mix you will have to enter the given anti freeze mix concentration in the Concentration field Then the application will recalculate the flow calculation using this value Also you can fi...

Page 12: ...of requested flow is entered the flow value in absolute units the percentage ratio from the previous paragraph will be displayed in the Flow field in the Measuring screen If you set up the requested...

Page 13: ...lly emerging pictures By rotating the pressure reset knob to the left the pressure inlets are hydraulically connected and physically there is zero pressure difference between them In the pressure meas...

Page 14: ...measurement you select the respective project and branch The Midor measuring instrument will set the valve and its preset automatically and you are ready for measuring The measured data will be again...

Page 15: ...opened in which you specify and enter the new project name Confirm it with the OK button After that the introductory Projects screen is reopened which already shows the new file name for storing the...

Page 16: ...ct selection list specify and enter the new project name for renaming confirm with the OK button Project Window Branches Tab Once the Branches tab is selected a screen is displayed where you can set u...

Page 17: ...Add branch selection list A screen is opened in which you specify and enter the new branch name and confirm with the OK button Rename Branch The Rename branch selection list A screen is opened in whi...

Page 18: ...ndependent periodical data recording This function may make the project diagnostics easier especially for irregular or long time processes The recorded data contains the record description date time s...

Page 19: ...ide Record Info Tab After clicking on the button the Record Info context menu is displayed where you can work with records using respective tabs Add new record Open record Save record as Read record S...

Page 20: ...two subsequent fields The last two fields of this screen are designed for specifying and entering the valve on which you are measuring and its preset Confirm the entry by the Continue to record option...

Page 21: ...a line opens into which you have to enter the name under which the record will be stored The file name extension is added automatically Send Record via Mail In order to have this function available y...

Page 22: ...nd calculations in balancing hydraulic systems There are the following four calculations in the Midor application 1 Preset calculation calculates the valve preset for the flow requested in the current...

Page 23: ...espective selection fields of the Calculations introductory screen Preset Calculation It calculates the valve preset in the current branch for the requested flow Enter the requested flow in the first...

Page 24: ...displays the result in the Calculations Results section of the screen Available Pressure Calculation Enter the requested flow in the first Available pressure calculation screen and confirm the entry w...

Page 25: ...ressure in the first Valve authority calculation screen with the valve closed and confirm with the Save button Measure the pressure in the next screen with the valve fully open and confirm with the Sa...

Page 26: ...Unscrew the pressure input using the 13 mm wrench replace the clogged filters with a new set screw the pressure inputs back and tighten Battery Replacement Unscrew the screws on the battery cover Rem...

Page 27: ...ation is unable to connect with the pressure unit after pressing Connect refer to the picture on page 9 Check the Mobile device setup If you have the Midor pressure unit paired with the mobile device...

Page 28: ...1 1 selected device option and want to measure with a different pressure unit address Here you will see the BT module address recorded by your option Delete the address and the application will again...

Page 29: ...battery type recommended by the manufacturer for replacement Information for Users on Collection and Disposal of Used Devices and Batteries This symbol on the device packing or in appended documents m...

Page 30: ...5 from nominal pressure range Water Resistance IP65 Medium temperature 5 to 90 C Calibration Validity 24 months Ambient temperature 5 to 50 C Dimensions l x w x d 180x80x52 mm Storage temperature 5 to...