INSTALLATION
Detection area
Detection area can be adjusted from a maximum range of 15 meters down to 7 meters by observing
the below settings
Hold time
Hold time refers to the time that the luminaire will remain at 100% brightness after no motion is
detected
Standby period
Refers to the time period that the luminaire will remain at low light level in the absence of movement
If set to “DISABLE”, the low light level will permanently be maintained until motion is detected
S1
Detection
Area
On
100%
-
50%
ON
S2
S3
S4
HOLD TIME
On
On
On
5sec
-
On
On
30sec
On
-
On
90sec
-
-
On
3min
On
On
-
20min
-
-
-
30min
S5
S6
S7
STANDBY
PERIOD
On
On
On
DISABLE
-
On
On
60min
On
-
On
30min
-
-
On
10min
On
On
-
5min
-
-
-
5sec
ON
ON