![ML Knightsbridge HBL Series Installation And Maintenance Manual Download Page 2](http://html.mh-extra.com/html/ml/knightsbridge-hbl-series/knightsbridge-hbl-series_installation-and-maintenance-manual_1813556002.webp)
2
These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
HBL100 / HBL150 / HBL200 / HBL240
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• Installation of this luminaire should only be carried out by a qualified electrician or competent
person to the latest Building and current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the
rating of the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for
installation
• This product series is Class I and requires an earth
• This product series is IP65 rated (recommended indoor use only)
• This product is dimmable via a 1-10V dimmer
• Provide power to the required point of installation. Suitable IP rated junctions boxes should be used
where required
Suspension mounting
• To suspend the fitting, screw the mounting hoop into the top of the luminaire (see Fig 1)
HBL series
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
HBL100 / HBL150 / HBL200 / HBL240
SAFETY
•
Installation of this luminaire should only be carried out by a qualified electrician or competent person to the
latest Building and current IEE Wiring Regulations (BS7671)
•
Please isolate mains prior to installation/maintenance
•
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
•
Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for installation
•
This product series is Class I and requires an earth
•
This product series is IP65 rated (recommended indoor use only)
•
This product is dimmable via a 1-10V dimmer
INSTALLATION
•
Provide power to the required point of installation. Suitable IP rated junctions boxes should be used where
required
Suspension mounting
•
To suspend the fitting, screw the mounting hoop into the top of the luminaire (see Fig 1)
Fig 1
Bracket mounting
•
Using the bracket as a template, mark the location of the fixing holes, drill 2x 10mm holes ensuring not to
infringe with any joists, gas or water pipes or electrical cables
•
Using a hammer, tap the expansion bolts into the 10mm fixing holes (see Fig 2)
Fig 2
Screw down
mounting hoop
Fig 1